en POLSKI
eISSN: 2449-6731
ISSN: 2449-6723
Prenatal Cardiology
Current issue Archive About the journal Editorial board Abstracting and indexing Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
1/2023
 
Share:
Share:
Research paper

The role of first-trimester single arterial vessel sign instead of a V-sign at the level of the three-vessel and tracheal view in screening for congenital heart diseases

Agnieszka Nocuń
1
,
Marcin Wiecheć
2
,
Magdalena Dudzik
1
,
Krzysztof Serafin
3

1.
Centre of Ultrasound Diagnostics MWU DobreUSG, Krakow, Poland
2.
Department of Gynecology and Obstetrics, Jagiellonian University Medical College, Krakow, Poland
3.
Specialistic Obstetrics and Gynecology Practice, ARS Medica, Tarnow, Poland
Prenat Cardio 2023: 1-12
Online publish date: 2023/12/21
Article file
Get citation
 
PlumX metrics:
 

Introduction

It is crucial to search for better screening strategies to more effectively detect congenital heart diseases (CHDs) in prenatal life, especially those that are ductal dependent. Despite many efforts from dedicated societies, prenatal detection rates (PDRs) of CHDs remain unsatisfactory, at an average level below 50% among multiple registries [1–3].
Starting from 1991, a number of authors raised the role in screening for CHDs of mid-gestational upper mediastinum fetal ultrasound projections including the following: 3-vessel (3VV), 3-vessel and trachea (3VTV), transverse aortic arch views, and a transverse section through the innominate vein [4–10]. Their major role is focused on the assessment of the number of arterial and venous vessels, their arrangement, proportion in size, flow directions, the relationship of these vessels with the trachea, and the size of the thymus. The characteristics of these views in major CHDs was widely described in the literature [9, 10]. In the normal heart 3VTV presents a V-sign formed by the confluence of transverse sections through the aortic and ductal arches together with the transverse sections through the trachea and superior caval vein on its right and the thymus in the front. Due to the small size of the fetal heart in the first trimester (FT), the whole sequence of upper mediastinum views and their detailed assessment in B-mode is difficult to reproduce. This is why most authors who share their interest in the first trimester screening for CHDs despite 4-chamber view focus on 3VTV in colour mapping, which is highly reproducible [11]. Several groups of authors stated that a reduced number of arterial vessels in 3VTV in connection with 4CV findings at the time of a first-trimester scan may indicate suspicion of major ductal-dependent (DD) CHDs, like d-transposition of the great arteries (D-TGA), but also hypoplastic left heart syndrome (HLHS), or tetralogy of Fallot (TOF) [12-16]. Until now, the power of the single arterial vessel in 3VTV to detect CHDs at the time of first-trimester screening was not measured in low- or high-risk populations.
We decided to conduct this study to assess the following: 1) to compare FT parameters and follow-up fetal, postnatal echocardiography and autopsy findings in fetuses presenting the single arterial vessel in 3VTV with fetuses presenting the “V-sign” at the level 3VTV in colour mapping (3VTVc) in correlation with 4CV findings; 2) to measure screening performance of the single arterial vessel in 3VTV and of indirect FT markers for CHDs.

Material and methods

This study was a prospective observational analysis. Patient enrolment was based on cooperation between 2 screening centres and one tertiary centre in an area of south Poland. The study population sample was collected between January 2016 and April 2019 and covered 2338 singleton pregnancy referrals for early cardiac scan after FT screening. The indications for early screening were as follows: maternal age above 35 years (287), family history factors (153), assisted reproduction techniques (384), maternal serum signs of infection (136), and/or sonographic signs suspicious for CHD, such as increased NT (431), increased FT risk for major trisomies (548), the presence of TR (234), or reversed a-wave in DV velocimetry (165). Exclusion criteria were as follows: multiple gestations, multiple anomalies, aneuploidy, and loss from follow-up. The maternal body mass index was calculated in kilograms per square metre on the day of the tertiary centre scan. All tertiary centre scans were performed within 7 days after FT screening. The scan protocol covered an early cardiac and extracardiac ultrasound scan, according to the steps described by Springhall et al. [17]. The scan was accompanied by the reassessment of primary (NT, fetal heart rate [FHR]) and secondary markers of aneuploidy (nasal bone, tricuspid flow, and ductus venosus velocimetry), according to recommendations from the Fetal Medicine Foundation [18]. For the purpose of an early cardiac scan in all cases, examiners insonated the fetal chest in a manner that the fetal spine was observed at a 6 or 12 o’clock position to avoid less optimal colour mapping views or oblique sections. Then, colour flow mapping was triggered for the shortest time possible. The perfect insonation angle to the interventricular septum of approximately 45° was certainly an easy approach to the levels of the 4-chamber view in colour mapping (4CVc) and 3VTVc, allowing for a smooth shift between these levels. This was consistent with our previous study protocol [19]. Experienced physicians examined subjects with Samsung WS80, Samsung HERA W10 (Samsung Electronics, Seoul, Korea), and Voluson E8 (GE Healthcare, Zipf, Austria) ultrasound scanners (M.W. and A.N.). The risk of major trisomies was not recalculated after first-line FT screening. The factory presets of the machines were adapted to obtain images of high diagnostic value and to ensure acceptable safety limits for an early cardiac scan: the mechanical index for B-mode imaging and the soft tissue thermal index in the colour flow mode were set not to exceed a value of 1. All scans were performed with a transabdominal 3–10 MHz or 4–8 MHz transducer. In suboptimal scanning conditions, a transvaginal 3-10 MHz or 5–9 MHz transducer was applied. The abovementioned standardized settings allowed for precise early cardiac imaging and restriction of the scan duration to meet the ALARA (as low as reasonably achievable) principle [20, 21]. All tertiary centre FT findings were recorded and documented. Next, all data concerning the second trimester, third trimester, up to 2 months postnatal or autopsy findings of enrolled patients were collected and included in a database. All referred subjects provided signed consent to participate in the study, and the local Ethics Committee approved the protocol. Enrolled subjects were grouped according to the FT tertiary centre picture of the 3VTVc into a “V-sign” subgroup and a single arterial vessel in the 3VTV subgroup. Ductal dependent anomalies in the study group were classically defined as cardiac lesions requiring postnatal maintenance of arterial duct patency due to the significant obstruction of flow to systemic or pulmonary circulation in simple or complex CHDs, or in parallel circulation circuits like those observed in D-TGA. Subjects’ characteristics were examined using descriptive statistics. Subsequently, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were calculated separately for each diagnostic algorithm. All calculations were performed using SPSS version 17 data analysis software (IBM Corporation, Armonk, NY). Findings with p < 0.05 were considered significant.

Results

Group characteristics

All scans were performed through a transabdominal approach, and 38 patients (1.87%) required an additional transvaginal evaluation to demonstrate early fetal cardiac views mapped with a colour Doppler.
Based on 2338 referrals, 2023 subjects were included in the study population, because 105 declined to participate, aneuploidy was revealed in 52, 20 presented multiple gestation, and 128 were lost to follow up. The median maternal body mass index was 22.5 kg/m2 (range 17.1–35.7) in the single arterial vessel in the 3VTV subgroup and 22.8 kg/m2 (range 17.3–35.8) in the “V-sign” subgroup; the difference was not statistically significant (p = 0.07). The study group characteristics, according to maternal age, gestational age, which was expressed by crown rump length (CRL) and gestational weeks according to FMF tables, FHR, NT, and DV PI, are presented in Table 1.
Single arterial vessel sign in 3VTV and “V-sign” subgroups were statistically significantly different in terms of gestational age (p = 0.017), NT thickness (0.000), and DV PI (p = 0.000), but these differences have no clinical impact due to small discrepancies in values between the groups (Table 1). Statistically significant differences were observed in terms of maternal age (p = 0.000), showing that fetuses presenting the single arterial vessel in 3VTV had younger mothers.
Among subjects presenting the single arterial vessel in 3VTV, analyses of tricuspid flow demonstrated 20 cases of TR (29.6%), and 50 cases of TR (2.6%) were observed in the “V-sign” group, which was a statistically significant difference (p = 0.000). A reversed a-wave pattern in DV velocimetry in the single arterial vessel in 3VTV subjects was discovered in 16 cases (23.5%) vs. in 35 cases in “V-sign” fetuses (1.8%), which was also a statistically significant difference (p = 0.000).

Congenital heart disease final diagnoses and follow-up

Among single arterial vessel sign in 3VTV fetuses, 2 normal fetal hearts and 66 CHDs were identified, including 42 ductal dependent lesions. The following anomalies were also found in this group: HLHS (16), aortic arch obstruction ± ventricular septal defect (10), double outlet right ventricle (DORV) (7), D-TGA (8), D-TGA + ventricular septal defect (6), double inlet left ventricle (DILV) (4), common arterial trunk (CAT) (2), pulmonary atresia with intact interventricular septum (PAIVS) (2), l-transposition of the great arteries (L-TGA) (2), tricuspid atresia (TA) (2), tetralogy of Fallot with absent pulmonary valve syndrome (ToF-APVS) (1), tetralogy of Fallot with pulmonary atresia (ToF-PA) (1), and 2 false-positive cases.
Among “V-sign” fetuses, 1913 normal fetal hearts and 42 CHDs were identified, including 2 ductal dependent lesions. The following anomalies were identified in this group: ventricular septal defect (VSD) (18), atrioventricular septal defect (AVSD) (3), ToF (2), pulmonary stenosis (PS) (2), aortic coarctation (CoA) (3), aortic stenosis (AS) (3), DORV (1), partial anomalous pulmonary venous return (PAPVR) (2), right aortic arch (RAA) (2), premature ductal constriction (2), aorto-pulmonary window (APW) (1), aortic tunnel (1), cor triatriatum (1), and total anomalous pulmonary venous return (TAPVR) (1).
A summary of the diagnosis time, postnatal findings, and follow-up among CHDs identified in the study group is shown in Table 2.

Video analysis of early cardiac images

For all patients the recorded clips were reviewed and representative images at the levels of the 4-chamber view, 3-vessel view, and 3-vessel and tracheal view were stored. Exemplar still images of representative cardiac views of analysed fetuses are shown in Figures 1–4.

Screening performance

Screening performance for the first-trimester 3VTVc picture of the single arterial vessel in 3VTV: for D-TGA and D-TGA + VSD, for the total number of CHDs, and for DD CHDs. These findings are presented in Table 3.
In the study population, screening performance for classic FT parameters, such as NT, TR, and DV PI > 95th percentile, was calculated for CHDs in general (Table 4) and for ductal-dependent CHDs (Table 5).

Discussion

Single arterial vessel sign in 3VTV at the time of late first trimester was described as a potential indicator of D-TGA, and because of that it became related only with this specific condition by first-trimester examiners [13, 14]. Our series, as the first in the literature, demonstrates that it should be rather understood as a strong indicator of DD CHDs at this time of gestation. On the other hand, we should not forget about all the limitations of the early cardiac assessment caused by limited image resolution or difficulty in scanning high-BMI patients, which potentially produces false positive and false negative cases. However, after a detailed analysis of pros and cons, the application of 3VTVc builds a strong screening line for DD CHDs including D-TGA.
According to multiple studies, there is no question about the importance of the prenatal diagnosis of D-TGA. It is of particular significance for fetuses with an intact ventricular septum because 4–12% of neonates will develop major hemodynamic alterations that can cause death shortly after birth [22–24]. Moreover, the total cost of initial hospitalization is higher for infants without a prenatal diagnosis of D-TGA [25]. It was also observed that if D-TGA is detected prenatally, there are no differences in postnatal outcomes, independent of whether a neonate was delivered in a specialist centre or a primary hospital [26].
Due to a lack of known maternal risk factors of fetal D-TGA, it is difficult to determine a group of patients who may be more at risk for this condition as a fetus. In recent years, increasing focus is placed on FT early cardiac screening [17, 27, 28]. Quartermain et al. analysed 31,374 patients from 91 centres between 2006 and 2012, and they showed that the DR for D-TGA with an intact interventricular septum was 27.9%, and that of VSD was 36.8% [1]. Van Velzen et al., based on an analysis of 724,089 deliveries, calculated D-TGA DRs of 50% in 2009 and 2010 and 41.7% in 2011 [29]. Another valuable report, which included 18,000 subjects from international birth defect surveillance programs, showed significant differences among countries, and even their regions, in prenatal DRs for D-TGA [30]. A breakthrough in prenatal diagnosis was discovered in the analysis of the national Dutch registry, which showed a significant increase in the DR of D-TGA from 44.2% to 82.4% after introducing mid-gestational 3-vessel view (3VV) into the routine mid-gestational ultrasound screening [31].
It must be emphasized that it is not only of importance to diagnose D-TGA prenatally, but also to check for prognostic factors like the ones indicating to the need for urgent atrio-septostomy after delivery. Słodki et al. have recently reported on the importance of the measurement of maximum velocity of flow in pulmonary veins in this context [32].
Regarding FT screening for CHDs, most authors paid more attention to indirect parameters. This indirect approach showed unsatisfactory results. As an example, Westin et al. reported an extremely low DR at the level of 13.5% of NT ≥ 95th percentile for isolated CHD, based on a low-risk population of 16,383 patients [19]. Their findings are comparable with our results (DR of 12.64%). Another retrospective analysis, based on more than 100,000 pregnancies, showed an FT DR of 13.3% with FT indirect ultrasound markers, and a second-trimester DR of 80% with direct cardiac views [33, 34]. Our group also examined tricuspid flow and DV velocimetry in FT observational studies and found no specific patterns for particular CHDs [35, 36].
On the other hand, some authors concluded that direct early cardiac evaluation is achievable and rational, giving parents the chance to exclude approximately 60% of CHDs and to comfort them about a normal cardiac anatomy as early as possible [15, 37–42]. Early detection of various forms of CHD has been widely reported in the literature [43–45]. The only obstacle in early cardiac evaluation may be the heart size at the time of FT scan. It is also of importance that patients with a high BMI may benefit from an early cardiac evaluation performed transvaginally. This is important because obesity was determined to be a crucial factor in reducing a prenatal diagnosis of D-TGA [46].
By using direct early fetal cardiac evaluation, Volpe et al. reported 4 cases of D-TGA that were correctly diagnosed at 11–14 weeks of gestation. Unfortunately, the authors did not state which of the ultrasound findings had been the most useful in supporting the identification of D-TGA [47].
The only specific descriptions of the early diagnosis methodology for D-TGA were given by Vinals in 8 cases and by Menahem et al. in 21 cases [13, 14]. They observed the following: 1) at the level of the 3VV, the ascending aorta was located more anteriorly than the main pulmonary artery; 2) at the level of the 3VTV, 2 vessels rather than 3 were observed; and 3) the great vessel arising from the anterior ventricle (aorta) running cranially presented an atypical convexity to the right. In our study, we tested their concept in a high-risk population, and we found that the single arterial vessel in 3VTV, which is equivalent to their observations regarding one arterial vessel at the level of the 3VTV, was highly sensitive (93.3%) and specific (97.3%) for D-TGA/D-TGA+VSD. It must be emphasized that not all D-TGA cases are detectable when using the single arterial vessel in 3VTV. Examiners should consider cases such as the one of ours shown in Figure 2, which was the consequence of VSD and severe rightward deviation of the infundibular septum, which allows the visualization of the “V-sign” at the level of 3VTVc throughout gestation instead of the single arterial vessel in 3VTV, which is characteristic for D-TGA. Surprisingly, as stated above, we found that the single arterial vessel sign in 3VTV was highly sensitive (95.8%) and specific (98.8%) for other ductal-dependent CHDs, which was not previously mentioned in the literature. Only 4.5% of ductal-dependent CHDs in our series presented the “V-sign” at the time of the FT scan. As an example, we found the single arterial vessel sign in 3VTV among the Taussig-Bing anomaly, HLHS, severe forms of aortic arch obstruction, PAIVS, ToF, and TA presenting severe right outflow tract obstruction. The first-trimester single arterial vessel in 3VTV was also present in non-ductal-dependent CHDs, such as L-TGA, or SV, which is usually connected with l- or d-transposed great arteries. It must be emphasized that the aim of the FT early cardiac scan is not to replace the second-trimester fetal echocardiography, but to select patients more effectively for detailed fetal cardiac assessment later in gestation, especially for D-TGA, which requires a better screening policy due to alarming prenatal DRs.

Conclusions

A key element of our study is the need to examine a high number of early cardiac scans performed in a high-risk population in a study group with a representative number of CHDs. Our findings and those published by other authors are very interesting because differentiation between the single arterial vessel sign in 3VTV and the “V-sign” is easily replicable and safe due to the short exposure time for colour mapping needed to obtain satisfactory images. In our opinion, if other independent groups of authors confirmed and routinely adopted the international guidelines as in latest updated ISUOG recommendations for fetal cardiac screening, this would help establish their use as another strong prenatal predictor of ductal-dependent CHDs including D-TGA [48].

Conflict of interest

The authors declare no conflict of interest.

REFERENCES

1. Quartermain MD, Pasquali SK, Hill KD, Goldberg DJ, Huhta JC, Jacobs JP, et al. Variation in prenatal diagnosis of congenital heart disease in infants. Pediatrics 2015; 136: e378-e385.
2. https://eu-rd-platform.jrc.ec.europa.eu/eurocat_en.
3. Escobar-Diaz MC, Freud LR, Bueno A, Brown DW, Friedman KG, Schidlow D, et al. Prenatal diagnosis of transposition of the great arteries over a 20-year period: improved but imperfect. Ultrasound Obstet Gynecol 2015; 45: 678-682.
4. Chaoui R, Bollmann R, Hoffmann H, Heling KS. Sonoanatomie des fetalen Herzens. Ultraschal Klin Prax 1991; 6: 59-67.
5. Yoo SJ, Lee YH, Kim ES, Ryu HM, Kim MY, Choi HK, et al. Three-vessel view of the fetal upper mediastinum: An easy means of detecting abnormalities of the ventricular outflow tracts and great arteries during obstetric screening. Ultrasound Obstet Gynecol 1997; 9: 173-182.
6. Yoo SJ, Lee YH, Cho KS. A clue to heart disease in the fetus. AJR Am J Roentgenol 1999; 172: 825-830.
7. Yagel S, Arbel R, Anteby EY, Raveh D, Achiron R. The three vessels and trachea view (3VT) in fetal cardiac scanning. Ultrasound Obstet Gynecol 2002; 20: 340-345.
8. Viñals F, Heredia F, Giuliano A. The role of the three vessels and trachea view (3VT) in the diagnosis of congenital heart defects. Ultrasound Obstet Gynecol 2003; 22: 358-367.
9. Tongsong T, Tongprasert F, Srisupundit K, Luewan S. The complete three-vessel view in prenatal detection of congenital heart defects. Prenat Diagn 2010; 30: 23-29.
10. Gardiner H, Chaoui R. The fetal three-vessel and tracheal view revisited. Semin Fetal Neonatal Med 2013; 18: 261-268.
11. Quarello E, Lafouge A, Fries N, Salomon LJ. Basic heart examination: feasibility study of first-trimester systematic simplified fetal echocardiography. Ultrasound Obstet Gynecol 2017; 49: 224-230.
12. De Robertis V, Rembouskos G, Fanelli T, Volpe G, Muto B, Volpe P. The three-vessel and trachea view (3VTV) in the first trimester of pregnancy: an additional tool in screening for congenital heart defects (CHD) in an unselected population. Prenat Diagn 2017; 37: 693-698.
13. Viñals F, Ascenzo R, Poblete P, Comas C, Vargas G, Giuliano A. Simple approach to prenatal diagnosis of transposition of the great arteries. Ultrasound Obstet Gynecol 2006; 28: 22-25.
14. Menahem S, Rotstein A, Meagher S. Rightward convexity of the great vessel arising from the anterior ventricle: a novel fetal marker for transposition of the great arteries. Ultrasound Obstet Gynecol 2013; 41: 168-171.
15. Wiechec M, Knafel A, Nocun A. Prenatal detection of congential heart disease at 11-13 weeks scan using a simple protocol of color Doppler of the four-chamber-view and the three-vessel and trachea view. J Ultrasound Med 2015; 34: 585-594.
16. Pasternok M, Nocun A, Knafel A, Grzesiak M, Orzechowski M, Konarska K, et al. “Y Sign” at the level of the 3-vessel and trachea view: an effective fetal marker of aortic dextroposition anomalies in the first trimester. J Ultrasound Med 2018; 37: 1869-1878.
17. Springhall EA, Rolnik DL, Reddy M, Ganesan S, Maxfield M, Ramkrishna J, et al. How to perform a sonographic morphological assessment of the fetus at 11-14 weeks of gestation. Australas J Ultrasound Med 2018; 21: 125-137.
18. https://fetalmedicine.org/fmf-certification/certificates-of-competence/nuchal-translucency-scan.
19. Westin M, Saltvedt S, Bergman G, Almström H, Grunewald C, Valentin L. Is measurement of nuchal translucency thickness a useful screening tool for heart defects? A study of 16 383 fetuses. Ultrasound Obstet Gynecol 2006; 27: 632-639.
20. Salvesen K , Lees C, Abramowicz JS, Brezinka C, ter Haar G, Maršál K. ISUOG statement on the safe use of Doppler in the 11 to 13 + 6-week fetal ultrasound examination. Ultrasound Obstet Gynecol 2011; 37: 628.
21. Toms DA. The mechanical index, ultrasound practices, and the ALARA principle. J Ultrasound Med 2006; 25: 560-561.
22. Bartlett JM, Wypij D, Bellinger DC, Rappaport LA, Heffner LJ, Jonas RA, et al. Effect of prenatal diagnosis on outcomes in d-transposition of the great arteries. Pediatrics 2004; 113: 335-340.
23. Bonnet D, Coltri A, Butera G, Fermont L, Kachaner J, Sidi D. Detection of transposition of the great arteries in fetuses reduces neonatal morbidity and mortality. Circulation 1999; 99: 916-918.
24. Soongswang J, Adatia I, Newman C, Smallhorn JF, Williams WG. Mortality in potential arterial switch candidates with transposition of the great arteries. J Am Coll Cardiol 1998; 32: 753-757.
25. Gupta D, Mowitz ME, Lopez-Colon D, Nixon CS, Vyas H V, Co-Vu JG. Effect of prenatal diagnosis on hospital costs in complete transposition of the great arteries. Prenat Diagn 2018; 38: 567-571.
26. Veal C, Hunt R, Tume LN. Do infants with transposition of the great arteries born outside a specialist centre have different outcomes? Cardiol Young 2019; 29: 1030-1035.
27. Committee CS. ISUOG Practice Guidelines: performance of first-trimester fetal ultrasound scan. Ultrasound Obstet Gynecol 2013; 41: 102-113.
28. Donofrio MT, Moon-Grady AJ, Hornberger LK, Copel JA, Sklansky MS, Abuhamad A, et al. Diagnosis and treatment of fetal cardiac disease: a scientific statement from the american heart association. Circulation 2014; 129: 2183-2242.
29. Van Velzen CL, Haak MC, Reijnders G, Rijlaarsdam MEB, Bax CJ, Pajkrt E, et al. Prenatal detection of transposition of the great arteries reduces mortality and morbidity. Ultrasound Obstet Gynecol 2015; 45: 320-325.
30. Bakker MK, Bergman JEH, Krikov S, Amar E, Cocchi G, Cragan J, et al. Prenatal diagnosis and prevalence of critical congenital heart defects: An international retrospective cohort study. BMJ Open 2019; 9: e028139.
31. Everwijn SMP, van Nisselrooij AEL, Rozendaal L, Clur SAB, Pajkrt E, Hruda J, et al. The effect of the introduction of the three-vessel view on the detection rate of transposition of the great arteries and tetralogy of Fallot. Prenat Diagn 2018; 38: 951-957.
32. Słodki M, Axt-Fliedner R, Zych-Krekora K, Wolter A, Kawecki A, Enzensberger C, et al. New method to predict need for Rashkind procedure infetuses with dextro-transposition of the great arteries. Ultrasound Obstet Gynecol 2018; 51: 531-536.
33. Minnella GP, Crupano FM, Syngelaki A, Zidere V, Akolekar R, Nicolaides KH. Diagnosis of major heart defects by routine first-trimester ultrasound examination: association with increased nuchal translucency, tricuspid regurgitation and abnormal flow in ductus venosus. Ultrasound Obstet Gynecol 2020; 55: 637-644.
34. Syngelaki A, Hammami A, Bower S, Zidere V, Akolekar R, Nicolaides KH. Diagnosis of fetal non-chromosomal abnormalities on routine ultrasound examination at 11-13 weeks’ gestation. Ultrasound Obstet Gynecol 2019; 54: 468-476.
35. Wiechec M, Nocun A, Wiercinska E, Beithon J, Knafel A. First trimester tricuspid regurgitation and fetal abnormalities. J Perinat Med 2015; 43: 597-603.
36. Wiechec M, Nocun A, Matyszkiewicz A, Wiercinska E, Latala E. First trimester severe ductus venosus flow abnormalities in isolation or combination with other markers of aneuploidy and fetal anomalies. J Perinat Med 2016; 44: 201-209.
37. Smrcek JM, Berg C, Geipel A, Fimmers R, Axt-Fliedner R, Diedrich K, et al. Detection rate of early fetal echocardiography and in utero development of congenital heart defects. J Ultrasound Med 2006; 25: 187-196.
38. Becker R, Wagner RD. Detailed screening for fetal anomalies and cardiac defects at the 11-13 weeks scan. Ultrasound Obstet Gynecol 2006; 27: 613-618.
39. Weiner Z, Weizman B, Belooosesky R, Goldstein I, Bombard A. Fetal cardiac scanning performed immediately following an abnormal nuchal translucency examination. Prenat Diagn 2008; 28: 934-938.
40. Huggon IC, Ghi T, Cook AC, Zosmer N, Allan LD, Nicolaides KH. Fetal cardiac abnormalities identified prior to 14 weeks’ gestation. Ultrasound Obstet Gynecol 2002; 20: 22-29.
41. Axt-Fliedner R, Chiriac A, Gembruch U. First and early second trimester fetal heart scanning. Ultraschall Med 2009; 30: 364-375.
42. Carvalho JS. Fetal heart scanning in the first trimester. Prenat Diagn 2004; 24: 1060-1067.
43. Knafel A, Wiecheć M, Nocuń A, Basta A. Transposition of great arteries (D-TGA) in the first trimester – a case report. Prenat Cardio 2013; 3: 22-27.
44. Nawara A, Radzymińska-Chruściel B, Respondek-Liberska M, Januszewska K, Malec E. First trimester diagnosis of absent pulmonary valve (APV): a case report of prenatal treatment with a review of literature and data from the Polish National Registry of Fetal Cardiac Pathology. Prenatal Cardiol 2014; 4: 18-22.
45. Rieder W, Eperon I, Meagher S. Congenital heart anomalies in the first trimester: from screening to diagnosis. Prenat Diagn 2023; 43: 889‐900.
46. Bertagna F, Rakza T, Vaksmann G, Ramdane-Sebbane N, Devisme L, Storme L, et al. Transposition of the great arteries: factors influencing prenatal diagnosis. Prenat Diagn 2014; 34: 534-537.
47. Volpe P, De Robertis V, Campobasso G, Tempesta A, Volpe G, Rembouskos G. Diagnosis of congenital heart disease by early and second-trimester fetal echocardiography. J Ultrasound Med 2012; 31: 563-568.
48. Carvalho JS, Axt-Fliedner R, Chaoui R, Copel JA, Cuneo BF, Goff D, et al. ISUOG Practice Guidelines (updated): fetal cardiac screening. Ultrasound Obstet Gynecol 2023; 61: 788-803.
This is an Open Access journal, all articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.