Original paper

A comparison of TG-43 and TG-186 dose calculation algorithms for treatment planning of intra-cavitary brachytherapy using tandem and ovoid applicator

Syed Mohamed Shajid
1
,
Lalit Mohan Aggarwal
1
,
Ankur Mourya
2
,
Sunil Choudhary
1
,
Gogul Priean
1
,
Ankita Singh
1
,
Saji Oommen
3

  1. Department of Radiotherapy and Radiation Medicine, Institute of Medical Sciences, Banaras Hindu University, Varanasi, Uttar Pradesh, India
  2. Subhash Chandra Bose Medical College, Jabalpur, (MP), India
  3. Department of Radiation Oncology, Indraprastha Apollo Hospital, New Delhi, India
J Contemp Brachytherapy 2024; 16, 4: 289-296
Online publish date: 2024/09/12
Article file
Get citation
 
 
1. Sung H, Ferlay J, Siegel RL et al. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 2021; 71: 209-249.
2. Nath R, Anderson LL, Luxton G et al. Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys 1995; 22: 209-234.
3. Nori D, Dasari N, Allbright RM. Gynecologic brachytherapy I: Proper incorporation of brachytherapy into the current multimodality management of carcinoma of the cervix. Semin Radiat Oncol 2002; 12: 40-52.
4. Beaulieu L, Carlsson Tedgren Å et al. Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: current status and recommendations for clinical implementation. Med Phys 2012; 39: 6208-6236.
5. Enger SA, Vijande J, Rivard MJ. Model-based dose calculation algorithms for brachytherapy dosimetry. Semin Radiat Oncol 2020; 30: 77-86.
6. Jacob D, Lamberto M, Lawrence LD et al. Clinical transition to model-based dose calculation algorithm: a retrospective analysis of high-dose-rate tandem and ring brachytherapy of the cervix. Brachytherapy 2017; 16: 624-629.
7. Ma Y, Lacroix F, Lavallée MC et al. Validation of the Oncentra Brachy Advanced Collapsed Cone Engine for a commercial 192Ir source using heterogeneous geometries. Brachytherapy 2015; 14: 939-952.
8. Safigholi H, Niatsetski Y, Song WY et al. Modeling of the direction modulated brachytherapy (DMBT) tandem applicator in a commercial oncentra brachy TPS using the advanced collapse cone engine (ACE) algorithm. Brachytherapy 2018; 17: S106-107.
9. Suit HD, Moore EB, Fletcher GH et al. Modification of Fletcher ovoid system for afterloading, using standard-sized radium tubes (milligram and microgram). Radiology 1963; 81: 126-131.
10. Haie-Meder C, Pötter R, Van Limbergen E et al. Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group(I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV. Radiother Oncol 2005; 74: 235-245.
11. ICRU Report 89. Prescribing, recording and reporting Brachytherapy for cancer of the cervix. Oxford University Press 2013.
12. Mondal K, Mourya A, Choudhary S et al. Plan quality score to evaluate the dwell time deviation restricted inverse planning by simulated annealing and graphically optimized treatment plans for template-based interstitial brachytherapy. Cancer Radiother 2023; 27: 196-205.
13. Mikell JK, Klopp AH, Gonzalez GM et al. Impact of heterogeneity-based dose calculation using a deterministic grid-based Boltzmann equation solver for intracavitary brachytherapy. Int J Radiat Oncol Biol Phys 2012; 83: e417-e422.
14. Georg P, Pötter R, Georg D et al. Dose-effect relationship for late side effects of the rectum and urinary bladder in magnetic resonance image-guided adaptive cervix cancer brachytherapy. Int J Radiat Oncol Biol Phys 2012; 82: 653-657.
15. Rivard MJ, Coursey BM, DeWerd LA et al. Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. Med Phys 2004; 31: 633-674.
Copyright: © 2024 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
 