eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

4/2017
vol. 9
 
Share:
Share:
Original paper

Inflatable multichannel rectal applicator for adaptive image-guided endoluminal high-dose-rate rectal brachytherapy: design, dosimetric characteristics, and first clinical experiences

Maximilian P. Schmid
,
Daniel Berger
,
Martin Heilmann
,
Jessica Bör
,
Bernd Wisgrill
,
Ursula Azizi-Semrad
,
Nicole Nesvacil
,
Richard Pötter
,
Christian Kirisits
,
Rainer Schmid

J Contemp Brachytherapy 2017; 9, 4: 359-363
Online publish date: 2017/07/27
Article file
- Inflatable.pdf  [0.31 MB]
Get citation
 
 

Purpose

Conservative treatment of locally advanced rectal cancer is currently receiving an increasing investigation, as surgery may significantly impair both short-term and long-term quality of life results. Whereas for T1 and T2 cancers, excellent results can be achieved using contact X-ray radiotherapy alone with 90% local tumor control rates [1], only 12-20% complete remissions are observed in more advanced tumors after standard preoperative radiochemotherapy with 45-50 Gy [2]. However, in these well-responding patients, local tumor control and cancer-specific survival do not appear to be inferior to patients undergoing preoperative radiochemotherapy and surgery [3]. To increase the response to radiochemotherapy, a local boost can be considered. A recent dose-response analysis revealed that a dose of 92 Gy would be required for a 50% tumor control rate [4]. Besides contact X-ray radiotherapy, high-dose-rate brachytherapy (HDR-BT) has been described as a boost technique [5,6,7]. The steep dose gradient of HDR-BT qualifies for localized, highly focused treatments of small volumes. However, an appropriately focused applicator system with asymmetrical dose distribution is required to achieve a therapeutic benefit with this dosimetric profile. In the following, we describe the design, technical and dosimetric characteristics of an in-house developed applicator allowing asymmetrical dose distribution, we report on the feasibility of its use, and present some preliminary clinical results.

Material and methods

Patients and treatment

Three patients with locally advanced rectal cancer were treated in 2014 and 2015 at the Department of Radiation Oncology of the Medical University of Vienna with primary radiochemotherapy and image-guided bra­chytherapy. Patient 1 was 65 years old with a T2 N1 adenocarcinoma of the distal rectum. Patient 2 was 82 years old and had a T3 N0 adenocarcinoma of the distal rectum. Patient 3 was 86 years old with a T3 N1 adenocarcinoma of the distal rectum. All patients were treated with 3D conformal external beam radiotherapy (EBRT) up to 50 Gy with 2 Gy per fraction. Target volume delineation for EBRT was based on the recommendations by Roels et al. [8]. Concomitant chemotherapy with capecitabine 1,650 mg/m2 was administered daily during EBRT. Patient 1 was treated initially in preoperative intent, but the patient then refused surgery, whereas patients 2 and 3 were considered upfront as medically unfit for surgery. Figure 1 shows the local tumor extension on T2-weighted magnetic resonance imaging (MRI) for patient 3: (A) before radiochemotherapy, and (B) at week 3 during radiochemotherapy. After radiochemotherapy, all three patients received an endorectal HDR-BT boost. The CTV at brachytherapy was defined based on the tumor extension at diagnosis, but adapted according to the thickness of the rectal wall at the time of brachytherapy.

Applicator

The applicator consists of an inflatable endorectal balloon (RectalPro 75, QLRAD Inc, Miami, Florida, USA) and six attached Foley catheters with 14 F diameter (Folysil, Coloplast, Humlebaek, Denmark). Shortened front ends of the Foley catheters with a length of 20 cm are fixed to each other as well as to the endorectal balloon. They are fixed at the tip of the catheters (in the axis of the endorectal balloon through the existing holes) and at the level of the buckling of the endorectal balloon. 24 cm plastic needles (OncoSmart ProGuide, Elekta, Stockholm, Sweden) with 6 F diameter are inserted into the lumen of each Foley catheter and are used as the brachytherapy applicators. The endorectal balloon can be inflated up to 60 ml, which results in 4.0-4.5 cm balloon diameter. The Foley catheters, with the brachytherapy applicators inside, are attached at the less inflatable side of the balloon (treatment area), and the more inflatable side of the balloon is used as a spacer towards the contralateral non-involved rectal wall. This construction results in an asymmetric arrangement of the brachytherapy source channels, which allows delivering a high dose to the target area while keeping the dose relatively low on the contra-lateral side of the rectum. Figure 2 shows the applicator in two different views.

Applicator commissioning, reconstruction, and treatment planning

Before clinical use, the fully mounted applicator was commissioned using a phantom computed tomography (CT) study. Therefore, autoradiography of the applicator was performed to define the offset (distance from the visible applicator tips to the first dwell positions) and the appropriate indexer length for the afterloader. A dummy wire was inserted into each plastic needle to visualize the first source position. When the needles were properly inserted into the Foley catheters, the offset according to our equipment and configuration was 8 mm when an indexer length of 1,407 mm for each channel was selected. For the reconstruction of the applicator, CT images with a slice thickness of 2 mm were used and each catheter was digitized. The average distance between catheters was 9.0 ± 0.4 mm with an active length of 4 ± 1 cm. The dose was normalized at 5 mm tissue depth, while additional dose points were defined at 0 mm (surface of the applicator 2 mm from the source), 2 mm, 5 mm, and 10 mm on the target side and on the applicator surface contra-laterally. Geometric optimization with a minor manual adjustment of dwell times was mainly performed to shape the dose according to the geometry and patients’ target volumes. In addition, a CTV encompassing the area of tumor extension at time of diagnosis and the thickness of the rectal wall at the time of brachytherapy was retrospectively delineated for dose-volume-histogram evaluation (Figure 3). Oncentra Brachytherapy 4.5.2 (Elekta, Stockholm, Sweden) was used for treatment planning.

Results

Clinical results

Patient 1 and patient 2 achieved complete endoscopic remission after EBRT and chemotherapy, whereas rectoscopy in patient 3 revealed residual tumor (Figure 4). Gross target volume (GTV) at diagnosis and clinical target volume (CTV) at brachytherapy were, respectively, 2.7 cm3 and 2.2 cm3 (45% involvement of the circumference of the rectum) in patient 1, 12.8 cm3 and 2.8 cm3 (45% involvement of the circumference) in patient 2, and 42.7 cm3 and 18.0 cm3 (60% involvement of circumference) in patient 3. Positioning of the applicator was well-tolerated by the patients who did not require any anesthesia. The fully mounted deflated applicator was inserted into the rectum according to the required rotation and insertion depth, and inflated up to 40-60 ml based on the patient’s tolerance. By inflating the balloon, the catheters were pressed against the rectal wall. The position of the applicator was checked with CT imaging and adjusted if necessary. After CT-based treatment planning with the inflated applicator in situ (see above), the treatment was applied without any complications and the applicator was removed directly after. The overall procedure including rectoscopy was performed within approximately 1-2 hours as an out-patient treatment. All three patients showed complete clinical remission after treatment. Currently, all the patients are alive with no evidence of disease. Patient 1 developed a superficial ulceration causing pain one year after treatment, which was treated conservatively. Patient 3 developed minor rectal bleedings. None of the patients required colostomy after radiotherapy.

Dosimetric results

For all three patients, a similar dose gradient was achieved. The surface dose on the target side was 204 ± 19% of the normalized dose at 5 mm (100%) tissue depth, 143 ± 8% at 2 mm, and 64 ± 3% at 10 mm, while the surface dose on the contra-lateral side was only a tenth of the dose to the target side, resulting in 20 ± 8%. The active length was 3 cm for patient 1, 4 cm for patient 2, and 5 cm for patient 3, with resulting TRAKs (total reference air kerma) of 0.19 cGy/1m, 0.27 cGy/1m, and 0.39 cGy/1m, respectively. While the dose prescriptions for patient 1 and patient 2 were 7 Gy at 5 mm for 2 and 3 fractions, respectively, patient 3 was treated with 10 Gy at 5 mm for 3 fractions. The D90 doses of the retrospectively delineated CTV were 7.5 Gy (EQD2 – equivalent dose at 2 Gy), 12.2 Gy (EQD2), and 12.2 Gy (EQD2) per fraction for patients 1, 2, and 3, respectively. In total (EBRT + all brachytherapy fractions), doses of 65 Gy (EQD2), 87 Gy (EQD2), and 87 Gy (EQD2) were delivered to the D90 of the CTV of patients 1, 2, and 3, respectively. Figure 3 shows the dose distribution of patient 3 in coronal and transverse views.

Discussion

Dose escalation to the tumor beyond the standard 45-50 Gy radiochemotherapy can be considered in cases of conservative treatment of locally advanced rectal cancer. Data, mainly from Lyon/Nice and Clatterbridge, indicate high local tumor control and survival rates for advanced tumors if an additional boost is applied [5,9,10]. Contact X-rays or brachytherapy currently appear to be the only effective and safe ways to reach the presumably required high doses of > 90 Gy [4]. Here, we described our experiences with our own applicator for adaptive image-guided endorectal HDR-BT. The applicator was designed to provide a high dose to the target volume, while simultaneously sparing the non-involved circumference of the rectum. This was enabled by adding an inflatable balloon as a spacer to the guiding tubes for the plastic needles. This configuration provides a steep dose gradient in the target volume, and substantially reduces the dose to the contralateral side. Jakobsen et al. [11] reported the use of a 20 mm cylinder as an applicator including additional shields. With this approach, an asymmetric dose profile can be achieved as well – approximately 30% of the prescribed dose reaches the contralateral side behind the shields [12]. However, a cylinder only allows for limited adjustments according to the individual anatomy. The fixation of the cranio-caudal applicator position in relation to the target, and the additional need for an advanced dose calculation algorithm to include shielding material into the dose calculation, raises some practical challenges. While the Novi Sad applicator uses a similar principle as our applicator, with an inflatable balloon allowing for a better fixation and asymmetric dose distribution, our applicator appears to provide a better dose ratio between target and not-involved rectal circumference. Our applicator could be easily inserted and was well- tolerated by the patients. Image-guided treatment planning was performed with CT, which allowed for further dose optimization. The dose distribution was reproducible in all three patients with minor variations. The first patient received a relatively low dose in two fractions of 7 Gy at 5 mm tissue depth, which was then increased to three fractions of 10 Gy at 5 mm tissue depth in the third patient. No major acute toxicity was observed. A comparison of the point dose parameters with the respective DVH-parameters shows (as previously reported, e.g. for cervical cancer [13]) substantial differences. Additional research will be necessary to clarify the clinical relevance of these differences. Further dose escalation might be considered based on results from the published series. With contact X-rays, three fractions of 30 Gy surface dose are recommended as a boost for advanced disease [14], while the optimal dose schedule for HDR-BT is not clear. The Montreal group applies three fractions of 10 Gy at 10 mm from the applicator surface (after 50.4 Gy EBRT), whereas the HERBERT trial recommends three fractions of 7 Gy at 10 mm from the applicator surface (after 39 Gy EBRT) [15]. Both contact X-rays and HDR-BT offers certain advantages in localized targeted treatment. While treatment with contact X-rays has biological and dosimetric advantages, and allows for direct sight of the tumor (“eye-guided treatment”), brachytherapy opens up the possibility for three-dimensional image-guided treatment planning and dose optimization and reporting. This allows a higher degree of freedom for individualized dose prescription, respecting tissue depths and tumor volumes, including bulkier and more infiltrative residual rectal tumors than those applicable for contact X-rays [16].

Conclusion

The use of the applicator was clinically feasible, and resulted in a stable and reproducible dose distribution. First clinical results are promising.

Conflict of interest

The Department of Radiotherapy at the Medical University of Vienna received financial and/or equipment support for research and educational purposes from Elekta Brachytherapy, Elekta AB and Varian Medical Systems, Inc.

References

1. Gérard JP, Ayzac L, Coquard R et al. Endocavitary irradiation for early rectal carcinomas T1 (T2). A series of 101 patients treated with the Papillon’s technique. Int J Radiat Oncol Biol Phys 1996; 34: 757-783.
2. Patel UB, Taylor F, Blomqvist L et al. Magnetic resonance imaging-detected tumor response for locally advanced rectal cancer predicts survival outcomes: MERCURY experience. J Clin Oncol 2011; 29: 3753-3760.
3. Renehan AG, Malcomson L, Emsley R et al. Watch-and-wait approach versus surgical resection after chemoradiotherapy for patients with rectal cancer (the OnCoRe project): a propensity-score matched cohort analysis. Lancet Oncol 2016; 17: 174-183.
4. Jakobsen A, Ploen J, Vuong T et al. Dose-effect relationship in chemoradiotherapy for locally advanced rectal cancer: a randomized trial comparing two radiation doses. Int J Radiat Oncol Biol Phys 2012; 84: 949-954.
5. Sun Myint A, Lee CD, Snee AJ et al. High dose rate bra­chytherapy as a boost after preoperative chemoradiotherapy for more advanced tumors: the Clatterbridge experience. Clin Oncol (R coll Radiol) 2007; 19: 711-719.
6. Vuong T, Devic S. High-dose-rate pre-operative endorectal brachytherapy for patients with rectal cancer. J Contemp Brachytherapy 2015; 7: 183-188.
7. Devic S, Vuong T, Moftah B. Advantages of inflatable multichannel endorectal applicator in the neo-adjuvant treatment of patients with locally advanced rectal cancer with HDR brachytherapy. J Appl Clin Med Phys 2005; 6: 44-49.
8. Roels S, Duthoy W, Haustermans K et al. Definition and delineation of the clinical target volume for rectal cancer. Int J Radiat Oncol Biol Phys 2006; 65: 1129-1142.
9. Gerard JP, Chapet O, Ramaioli A, Romestaing P. Long-term control of T2-T3 rectal adenocarcinoma with radiotherapy alone. Int J Radiat Oncol Biol Phys 2002; 54: 142-149.
10. Gerard JP, Frin AC, Doyen J et al. Organ preservation in rectal adenocarcinoma (T1) T2-T3 Nx M0. Historical overview of the Lyon Sud - Nice experience using contact X-ray brachytherapy and external beam radiotherapy for 120 patients. Acta Oncol 2015; 54: 545-551.
11. Jakobsen A, Mortensen JP, Bisgaard C et al. Preoperative chemoradiation of locally advanced T3 rectal cancer combined with an endorectal boost. Int J Radiat Oncol Biol Phys 2006; 64: 461-465.
12. Poon E, Reniers B, Devic S et al. Dosimetric characterization of a novel intracavitary mold applicator for 192Ir high dose rate endorectal brachytherapy treatment. Med Phys 2006; 33: 4515-4526.
13. Tanderup K, Nielsen SK, Nyvang GB et al. From point A to the sculpted pear: MR image guidance significantly improves tumour dose and sparing of organs at risk in brachytherapy of cervical cancer. Radiother Oncol 2010; 94: 173-180.
14. Gerard JP, Chapet O, Nemoz C et al. Improved sphincter preservation in low rectal cancer with high-dose preoperative radiotherapy: the lyon R96-02 randomized trial. J Clin Oncol 2004; 22: 2404-2409.
15. Sun Myint A, Lee CD, Gerard JP. Rectal cancer. The GEC ESTRO Handbook of Brachytherapy. 2nd ed. 2014.
16. Nout RA, Devic S, Niazi T et al. CT-based adaptive high-dose-rate endorectal brachytherapy in the preoperative treatment of locally advanced rectal cancer: Technical and practical aspects. Brachytherapy 2016; 15: 477-484.
Copyright: © 2017 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.