eISSN: 1731-2531
ISSN: 1642-5758
Anaesthesiology Intensive Therapy
Current issue Archive Manuscripts accepted About the journal Supplements Editorial board Reviewers Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
2/2022
vol. 54
 
Share:
Share:
abstract:
Original paper

Integrated ultrasound protocol in predicting weaning success and extubation failure: a prospective observational study

Riddhi Kundu
1
,
Dalim K. Baidya
2
,
Rahul K. Anand
2
,
Souvik Maitra
2
,
Kapil D. Soni
3
,
Rajeshwari Subramanium
2

  1. Department of Critical Care Medicine, Manipal Hospitals, New Delhi, India
  2. Department of Anaesthesiology, Pain Medicine, and Critical Care, All India Institute of Medical Sciences(AIIMS), New Delhi, India
  3. Department of Trauma and Critical Care, All India Institute of Medical Sciences(AIIMS), New Delhi, India
Anaesthesiol Intensive Ther 2022; 54, 2: 156–163
Online publish date: 2022/04/12
View full text Get citation
 
PlumX metrics:
Background
Difficulty in weaning from mechanical ventilation is encountered in appro­ximately 20% of patients in the intensive care unit. We assessed the utility of a combined lung, diaphragmatic, and cardiac ultrasound protocol to predict extubation failure.

Material
All patients extubated following a successful spontaneous breathing trial (SBT) were included in the study. Lung ultrasonography score (LUS), diaphragmatic thickness fraction (DTF), changes in velocity time integral (VTI) to passive leg raise at the beginning of SBT, and change in LUS following SBT were recorded.

Results
A total of 60 patients who underwent successful SBT were included in the study. Twenty-seven patients required either non-invasive or invasive mechanical ventilation during the next 48 hours and were classified as weaning failure (Group F). The remaining 33 patients were designated as weaning success (Group S). Compared to group S, patients in Group F had significantly longer ICU length of stay (6.96 ± 4.30 days vs. 11.66 ± 3.85 days, P < 0.001), higher LUS change during SBT (1 [0–2] vs. 2 [1–4], P < 0.001), lower DTF (30.87 ± 5.32 vs. 27.88 ± 6.24, P = 0.04), and showed lower VTI increment to PLR (13.63 ± 3.44 vs. 9.11 ± 4.59, P < 0.001). Using a binary logistic regression model, DTF < 26% (odds ratio 6.20, 95% CI: 1.06–36.04) and VTI change to PLR < 10.2% (odds ratio 6.16, 95% CI: 1.14–33.13) were found to be significant predictors of weaning failure (P < 0.05). The AUROC for VTI and DTF for predicting weaning failure were 0.79 and 0.64, respectively.

Conclusions
An integrated ultrasound protocol using a combination of lung, diaphragm, and cardiac sonography was a reliable predictor of weaning failure.

keywords:

mechanical ventilation, weaning, ultrasound