eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

4/2017
vol. 9
 
Share:
Share:
Original paper

Is intraoperative real-time dosimetry in prostate seed brachytherapy predictive of biochemical outcome?

Daniel Taussky
,
Levon Igidbashian
,
David Donath
,
Dominic Béliveau-Nadeauv
,
Renée X. Larouche
,
Yanick Hervieux
,
Guila Delouya

J Contemp Brachytherapy 2017; 9, 4: 304-308
Online publish date: 2017/06/22
Article file
- Is intraoperative.pdf  [0.21 MB]
Get citation
 
 

Purpose

In 2001, the American Brachytherapy Society (ABS) provided their critical assessment on intraoperative (IO) planning in prostate permanent seed low-dose-rate brachytherapy (LDR-BT) with 125I, and gave recommendation for an online real-time IO dosimetry [1]. In 2010, the Groupe Européen de Curiethérapie and the European Society for Radiotherapy & Oncology (GEC-ESTRO) group discussed the various ways to use real-time dosimetry and described the basic approaches involving IO planning within the operating room (OR). This consisted of interactive planning with modification of the treatment based on the feedback of the real-time tracking of the actual needle positions and a continuous feedback of the seed positions as they were implanted [2]. In 2008, we described our results with an interactive planning technique using real-time three-dimensional (3D) transrectal ultrasound (TRUS) for dose planning and IO navigation [3], and reported the clinical outcome, toxicity [4,5], and seed loss [6] for low to high activity seeds. We described that IO dosimetric parameters on TRUS could predict a good quality implant on the Day 30 computed tomography (CT) scan. We also discovered that a good IO preimplant plan was the best predictive factor of a good implant on Day 30 [3]. In this present study, we updated our experience with a larger than previously described cohort and investigated whether IO TRUS-based dosimetry was predictive of biochemical recurrence (BR).

Material and methods

Of the first 251 patients who were treated with LDR-BT at our department, complete data were available for 238 (95%) patients. A postoperative dosimetry was not obtained due to technical difficulties in the other 5% of patients. In all patients, TRUS (BK Medical Systems, Harlev, Denmark) was performed immediately after the implant of two fixation needles. This TRUS was used for IO pre-planning (preimplant IO dosimetry). The planning and seed delivery were performed using the Nucletron FIRST system (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) with IO interactive planning, dynamic dose calculation, virtual needle guidance, robotic seed delivery, and needle retraction system. Immediately after implantation, an additional TRUS study was performed with the fixation needles still in place. Prostate delineation was repeated within the planning system a few days after the implant on the postoperative TRUS images, and the dosimetry to the prostate was recalculated (postimplant IO dosimetry). Slice thickness on both TRUS studies was 2.5 mm.
All patients had CT-based dosimetry performed at 30 days (Day 30) after the implant. The implant technique and dosimetry were performed as previously described [3]. Slice thickness was 3 mm.

Statistical analysis

Correlations between variables were calculated using the Pearson correlation coefficient. The value of IO dosimetry to predict Day 30 dosimetry was calculated using area under the receiver operating characteristic (AUROC) curves.
BR was defined according to the Phoenix definition (PSA = nadir + 2 ng/ml). Survival analyses were performed using the Kaplan-Meier method and were compared using the log-rank test.

Results

Table 1 lists patient and dosimetric characteristics of the 236 patients analyzed. Compared to the preimplant IO dosimetry, the postimplant D90 median was 3.8 Gy lower (interquartile range [IQR], 12.4-0.9), and the V100 was 1% less (IQR, 2.9-0.2%). The postimplant IO D90 was a median of 9.6 Gy higher (IQR, 9.5-30.3 Gy) than on Day 30, and the postimplant V100 was 3.2% higher (0.2-8.9%) than on Day 30. See Table 2 for differences in dosimetry at the different time-points. The quality of the implant measured with the D90 and V100 did not change significantly over time. Only the postimplant V100 value increased slightly with the year of implantation (r = 0.19, p = 0.004), but not the D90 without any effect on preimplant or Day 30 values (data not shown).
Figure 1 illustrates the correlation between the preimplant and the postimplant D90, and Figure 2 shows the correlation between the postimplant D90 and the D90 on Day 30 as a scatterplot. Both the postimplant IO D90 (AUC = 0.62, p = 0.038) and the preimplant IO D90 (AUC = 0.61, p = 0.046) were significant predictors of the D90 at Day 30. However, the false positive rate to predict for a D90 ≥ 130 Gy for different cut-offs was too high to identify ideal cut-offs. The D90 on Day 30 weakly correlated with the postimplant D90 (r = 0.13, p = 0.05) and with the prostate volume (r = 0.26, p < 0.001). On Day 30, the D90 was < 130 Gy in 13% of the patients.
Neither the preimplant nor the postimplant V100 showed a clear correlation with the V100 on Day 30. The postimplant V100 had the better predictive ability (AUC = 0.64, p = 0.015) for a V100 of < 85% (14% of patients) on Day 30 than the preimplant V100 (p = 0.08).
The median follow-up for patients without BR was 96 months (IQR, 66-108). The 5-year and 8-year BR-free rate was 96% and 90%, respectively. To identify cut-off values predictive of BR, we used quartiles of the D90 of the preoperative, postoperative, and Day 30 values. None of these quartiles showed any predictive value. This was also true when applied for a cut-off of 130 Gy for the D90 of Day 30 (detailed results not shown, all p ≥ 0.2). The year of the implant also did not have an influence on BR (p = 0.8). To account for a possible learning-curve, we repeated the analysis, this time excluding the first 10% (n = 23) of patients. None of the tested quartiles or the D90 on Day 30 was predictive of BR. Neither were such factors as Gleason score, PSA, or PSA-density (results not shown).

Discussion

We present one of the largest studies on IO planning and dose-delivery for prostate LDR-BT with a long follow-up. We discovered that a high D90 on the preplanning as well as on the postoperative TRUS were predictive of a good (≥ 130 Gy) D90. In addition, a high V100 on the postoperative TRUS dosimetry was significantly (p = 0.015) predictive of a V100 ≥ 85%, although the AUC (0.64) was low, making this measurement an unreliable factor. However, due to the relatively low AUC value (< 0.7) of all values and a lack of correlation between the values on Day 30 and the IO values, we determined that the IO dosimetry cannot reliably predict for Day 30 dosimetry. Therefore, Day 30 dosimetry remains the gold-standard in the evaluation of implant quality. In fact, many studies published before about 2010 have shown Day 30 dosimetry to predict for BR [7]. With a median follow-up of 8 years, we sought to identify cut-offs from IO dosimetry to predict BR. The fact that the quartiles, including the worst versus best quartiles of IO and Day 30, did not predict for BR, is likely due to the small sample size of 238 patients.
Others have described positive results in patients treated with intraoperative planning [8]. Indeed, our results are similar to a recent publication by Shukla et al. [9] using real-time intraoperative planning. They describe an eight-year BR-free rate of 87-92%, comparable to our 90% and, as in our present study, an absence of any dosimetric parameters predicting BR. Another reason for the lack of predictive value of dosimetry might be that there are many other factors that may play a role in outcome determination such as classical risk factors for biochemical recurrence including PSA and Gleason score as well as PSA density, which was recently described by our group [10].
Day 30 dosimetry is more accurate and less interobserver-dependent when performed with magnetic resonance imaging (MRI)-CT fusion than with CT alone, and is more accurate for prostate-sector analysis [11,12]. In fact, the use of MRI in the evaluation of postimplant dosimetry has recently been recommended by the American College of Radiology (ACR) [13].
The reasons why dosimetry decreases from preimplant to postimplant, and then to Day 30 are manifold. First, the decrease in dosimetry from preimplant to postimplant is influenced by factors such as non-anticipated pubic-arch interference and prostate swelling during the implant. The decrease to Day 30 is influenced by difficulties during the procedure in correctly identifying the prostate, and probably most importantly, intraprostatic migration after the implant [14] and seeds being displaced by the movement of the needle, or the creation of a vacuum or tunnel in the prostatic tissue by the needle. Another factor influencing dosimetry could be urinary catheter placement [15], but no catheter was placed on Day 30, although catheters are in place intraoperatively. Furthermore, we didn’t evaluate interobserver or intraobserver variability in contouring the prostate on TRUS, which is lower than on CT and has a smaller effect on dosimetry. This is due to the better soft-tissue contrast at the prostate border on TRUS [16,17]. It is known that very small changes on CT contouring can have a large effect on dosimetry [18].
Unfortunately, with the present software, we find it very difficult to analyze which seeds were displaced and by how much.
Evaluation and comparison of prostate contours before and after the implant are difficult. In our study, the preimplant dosimetry was done after the implantation of 2 fixation needles, which caused significant prostate edema. Although we previously found that the edema caused by the implant compared to the prostate volume after the insertion of the fixation needles was small (mean 1.9 cc) [19]; the prostate borders are more difficult to accurately define after the implant because of the edema and other artifacts caused by the procedure. The best way to analyze the reasons for the decline in dosimetry would be to use magnetic resonance imaging (MRI) immediately after the implant as well as on Day 30. Another more feasible option to improve intraoperative prediction of Day 30 dosimetry is the use of intraoperative fusion computed tomography [20].
The major limitation of IO planning with most currently available IO planning systems is the inability to adequately update the delivered seed position [1]. This may explain the absence of a meaningful intraoperative prediction of Day 30 dosimetry and BR in our present study. Other weak points of our study are that there was no IO protocol for the several physicists in the OR. Therefore, planning practices as well as when and how to update the needle position, may have differed between physicists. The treated patients represent the first cases of LDR-BT in our department. Although learning-curve effect on the implant quality and technique is probable, our long-term biochemical results are comparable with the literature. The same physician contoured the prostates on TRUS as well as on CT on Day 30. We therefore did not account for interobserver variability in contouring.
Intraoperative planning techniques were developed to overcome some of the shortfalls of the classic preplanning approach. These shortfalls include difficulties in matching the prostate TRUS image from the preplan to the IO position, adjusting for prostate shape and volume changes, and the additional work and discomfort to the patients caused by preplanning study. As such, IO planning has many advantages. Real-time IO treatment planning software with inverse planning optimization has been shown to achieve excellent implants [21,22]. Several centers have shown better dosimetric results from IO planning, as reviewed by Polo et al. [2]. To our knowledge, this is the first study with an exceptionally long follow-up, analyzing the impact of IO preimplant and postimplant dosimetry on BR.
Intraoperative 3D dose-planning has been shown to reduce the dose to the rectum and urethra, and allows for a reduction in numbers of seeds and mCi delivered [23]. IO with inverse optimization, as used in our cohort, has also been shown to produce less urethral dose, and a better implant than computer-assisted optimization methods modified peripheral and geometric optimization. Furthermore, it has been shown to result in a higher median V10 and D90 with fewer needles and seeds [24].

Conclusions

In conclusion, we found that IO dosimetry was predictive of Day 30 dosimetry, but with a low predictive value. We could not identify IO dosimetry that would predict biochemical outcome. We, therefore, conclude that postoperative CT- and MRI-based dosimetry remains the gold standard for evaluation of implant quality [12,25]. The incorporation of functional imaging, MRI-based IO planning, or use of robotics in seed delivery requires further study to determine if they will improve IO planning.

Disclosure

Authors report no conflict of interest.

References

1. Nag S, Ciezki JP, Cormack R et al. Intraoperative planning and evaluation of permanent prostate brachytherapy: report of the American Brachytherapy Society. Int J Radiat Oncol Biol Phys 2001; 51: 1422-1430.
2. Polo A, Salembier C, Venselaar J et al. Review of intraoperative imaging and planning techniques in permanent seed prostate brachytherapy. Radiother Oncol 2010; 94: 12-23.
3. Igidbashian L, Donath D, Carrier J-F et al. Poor predictive value of intraoperative real-time dosimetry for prostate seed brachytherapy. Int J Radiat Oncol Biol Phys 2008; 72: 605-609.
4. Tétreault-Laflamme A, Zilli T, Meissner A et al. The Quadrella: A novel approach to analyzing optimal outcomes after permanent seed prostate brachytherapy. Radiother Oncol 2014; 111: 110-113.
5. Zilli T, Taussky D, Donath D et al. Urethra-sparing, intraoperative, real-time planned, permanent-seed prostate brachytherapy: toxicity analysis. Int J Radiat Oncol Biol Phys 2011; 81: e377-383.
6. El-Bared N, Sebbaq N, Béliveau-Nadeau D et al. Seed loss in prostate brachytherapy. Strahlenther Onkol 2016; 192: 305-311.
7. Potters L, Roach M 3rd, Davis BJ et al. Postoperative nomogram predicting the 9-year probability of prostate cancer recurrence after permanent prostate brachytherapy using radiation dose as a prognostic variable. Int J Radiat Oncol Biol Phys 2010; 76: 1061-1065.
8. Guinot JL, Ricós JV, Tortajada MI et al. Comparison of permanent 125I seeds implants with two different techniques in 500 cases of prostate cancer. J Contemp Brachytherapy 2015; 7: 258-264.
9. Shukla G, Sarkar A, Hanlon A et al. Biochemical control and toxicity for favorable-and intermediate-risk patients using real-time intraoperative inverse optimization prostate seed implant: Less is more! Brachytherapy 2017; 16: 490-496.
10. Benzaquen D, Delouya G, Ménard C et al. Prostate-specific antigen density is predictive of outcome in suboptimal prostate seed brachytherapy. Brachytherapy 2017; 16: 348-352.
11. Maletz KL, Ennis RD, Ostenson J et al. Comparison of CT and MR-CT fusion for prostate post-implant dosimetry. Int J Radiat Oncol Biol Phys 2012; 82: 1912-1917.
12. Crook J, McLean M, Yeung I et al. MRI-CT fusion to assess postbrachytherapy prostate volume and the effects of prolonged edema on dosimetry following transperineal interstitial permanent prostate brachytherapy. Brachytherapy 2004; 3: 55-60.
13. Davis BJ, Taira AV, Nguyen PL et al. ACR appropriateness criteria permanent source brachytherapy for prostate cancer. Brachytherapy 2016, 16: 266-276.
14. Wang Y, Nasser NJ, Borg J, Saibishkumar EP. Evaluation of the dosimetric impact of loss and displacement of seeds in prostate low-dose-rate brachytherapy. J Contemp Brachytherapy 2015; 7: 203-210.
15. Kunogi H, Yamaguchi N, Wakumoto Y, Sasai K. Effect of a urinary catheter on seed position and rectal and bladder doses in CT-based post-implant dosimetry for prostate cancer brachytherapy. J Contemp Brachytherapy 2015; 7: 211-217.
16. Xue J, Waterman F, Handler J, Gressen E. The effect of interobserver variability on transrectal ultrasonography-based postimplant dosimetry. Brachytherapy 2006; 5: 174-182.
17. Haworth A, Ebert M, Clair SS et al. Impact of selection of post-implant technique on dosimetry parameters for permanent prostate implants. Brachytherapy 2005; 4: 146-153.
18. Mashouf S, Safigholi H, Merino T et al. Sensitivity of clinically relevant dosimetric parameters to contouring uncertainty in postimplant dosimetry of low-dose-rate prostate permanent seed brachytherapy. Brachytherapy 2016; 15: 774-779.
19. Chira C, Delouya G, Larrivée S et al. Prostate volume changes during permanent seed brachytherapy: an analysis of intra-operative variations, predictive factors and clinical implication. Radiat Oncol 2013; 8: 177.
20. Ishiyama H, Sekiguchi A, Satoh T et al. Dosimetry of permanent interstitial prostate brachytherapy for an interoperative procedure, using O-arm based CT and TRUS. J Contemp Brachytherapy 2016; 8: 7-16.
21. Zelefsky MJ, Yamada Y, Cohen GN et al. Intraoperative real-time planned conformal prostate brachytherapy: post-implantation dosimetric outcome and clinical implications. Radiother Oncol 2007; 84: 185-189.
22. Beaulieu L, Evans DA, Aubin S et al. Bypassing the learning curve in permanent seed implants using state-of-the-art technology. Int J Radiat Oncol Biol Phys 2007; 67: 71-77.
23. Raben A, Chen H, Grebler A et al. Prostate seed implantation using 3D-computer assisted intraoperative planning vs. a standard look-up nomogram: Improved target conformality with reduction in urethral and rectal wall dose. Int J Radiat Oncol Biol Phys 2004; 60: 1631-1638.
24. Raben A, Sammons S, Sim S et al. Initial comparison of inverse optimization, modified peripheral technique, and geometric optimization as real-time intraoperative computer planning options for permanent seed implantation of the prostate. Brachytherapy 2007; 6: 238-245.
25. Polo A, Cattani F, Vavassori A et al. MR and CT image fusion for postimplant analysis in permanent prostate seed implants. Int J Radiat Oncol Biol Phys 2004; 60: 1572-1579.
Copyright: © 2017 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.