eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

3/2014
vol. 6
 
Share:
Share:

Original paper
A simple technique for the generation of institution-specific nomograms for permanent prostate cancer brachytherapy

Kyle J. Lafata
,
Harry Bushe
,
Jesse N. Aronowitz

J Contemp Brachytherapy 2014; 6, 3: 293–296
Online publish date: 2014/09/23
Article file
- a simple technique.pdf  [0.16 MB]
Get citation
 
 

Purpose

Mathematical models (nomograms [1-6], nomographs [7], algorithms [8], reference [9] or look-up tables [10,11], and tie-line charts [12]) have long been used as aids for prostate brachytherapy. They are formulations to ‘pre-determine the total required isotope activity for performing transperineal interstitial permanent prostate brachytherapy’ from the pre-implant prostate volume [1]. They can be derived from statistical analysis of clinical data [3-5,10], or based upon a theoretical model of the activity needed to subsume a spheroidal volume with a prescription dose cloud [1,6-8,11,12]. Although their role has diminished in the era of computerized dosimetry [13,14], nomograms are still used as an independent check of pre-plans, and some brachytherapists utilizing intra-operative planning rely on them to determine the number and strength of seeds in their pre-implant seed order.
As implant preferences (prescription dose, seed distribution pattern, extra-capsular seed placement, organ constraints) differ among institutions, it has been recommended that each institution derive nomograms reflective of their program’s implant philosophy [3,15]. We relate a simple method, utilizing ubiquitous spreadsheet software, to generate institution-specific nomograms for the calculation of seed number and strength for permanent prostate brachytherapy.

Material and methods

The process presented here relies on the analysis of previous implants. For purposes of illustration, we present the process we used to generate a nomogram based on the first 40 consecutive Cs-131 (131Cs) implants performed when our program transitioned to caesium sources (this study, including review of patient records, has been approved by our institution’s review board). The implants had been pre-planned, without intentional placement of extracapsular seeds. Post-implant dosimetry was based upon CT scans performed two weeks after implantation.

To generate a nomogram by this process, you will need: 1. Spreadsheet software; we used Excel 2011 for Mac, 14.1 (Microsoft Corporation, Redmond, WA, USA).
2. Post-implant dosimetry for 30 or more prostate implants, that had been analyzed by prostate brachytherapy dosimetry software; we used VariSeed v. 8.0 (Varian Medical Systems, Inc., Palo Alto, CA, USA). The implants should reflect your institution’s implant philosophy (prescription dose, loading pattern, use of extracapsular seeds, organ constraints). Both ‘full’ (monotherapy) and ‘partial’ (intended to be combined with external radiation) implants can be used.
3. Defined prescription dose and constraints. Ours were:
– prescription dose: 110 Gy for monotherapy, 70 Gy for partial implants;
– constraints: a) D90 range: 100-120% of prescription dose; b) optimal D90: midpoint of the D90 range (in our case, 110% of prescription dose; for monotherapy, 121 Gy); c) V150 constraint: ≤ 60% of prostate;
d) V100rectum constraint: < 0.75 mL.

The process. 1. Generate a spreadsheet that contains data from patient records and post-implant dosimetry. Column headings are: a) case identifier; b) pre-implant prostate volume; c) number of seeds implanted; d) activity per seed; e) ‘actual’ total implant activity (the product of columns ‘c’and ‘d’); f) ‘optimal’ total implant activity (see step 2).
2. Determine ‘optimal’ total implant activity for each implant using the dosimetry software and post-implant dosimetry, manipulate the individual seed strength for each case (including ‘partial’ implants) so that each implant achieves an optimal D90 (in our case, 121 Gy). Do not add, delete, or move seeds. All seeds must be of the same strength. Once the D90 range is achieved, do not further manipulate the strength of seeds if it would lead to a dose distribution that would exceed constraints (V150 or V100rectum).
3. Using the spreadsheet software, generate Cartesian (scatter) plots with the ‘number of seeds’ (Y axis) as a function of ‘prostate volume’ (X axis). Fit to a linear or power regression. Display the equation and R2.
4. Using the spreadsheet software, generate Cartesian (scatter) plots with ‘optimal’ total activity (Y axis) as a function of ‘prostate volume’ (X axis). Fit to a linear or power regression. Display the equation and R2.
5. You now have equations that can predict the appropriate number of seeds and total implant activity for an implant of a prostate of a given volume. Or, you can generate a ‘look-up table’. With the equations generated in steps 3 and 4, create a look-up table for the range of volumes likely to be implanted (say, 20-60 mL).

The columns being:
a) prostate volume (every integer in the range of volumes);
b) number of seeds (solve for Y, using the equation generated in step 2, where X is the prostate volume);
c) ‘optimal’ total implant activity (solve for Y, using the equation generated in step 3, where X is the prostate volume);
d) activity per seed (divide column c by column b).
It is advisable to order a few extra seeds to compensate for seed loss or the discovery of a larger than anticipated prostate volume at time of implantation. The nomogram can assist in making appropriate adjustments in total implant activity in the operating theatre if the prostate volume is determined to be different than measured pre- operatively (e.g., due to the action of hormonal therapy).

Results

Our first 10 131Cs implants guided by the nomogram generated by this method were analyzed. The post-implant dosimetric outcomes are summarized in Table 1.
Not surprisingly, the degree of post-implant swelling, expressed as the ratio of post-implant prostate volume (on CT performed 2 weeks after implantation) to pre-implant prostate volume (measured by ultrasound) greatly influenced post-implant dosimetry metrics. The median ratio was 1.28, but the range was 1.12-1.56. The implant with the greatest degree of swelling (ratio 1.56) had the ‘coolest’ D90 (101%) and V150 (42%). The implant with the least swelling (ratio 1.12) had the ‘warmest’ D90 (124%) and V150 (70%); the latter was the only implant in which constraints were not met.
The volume of tissue encompassed by the prescription dose on the post-implant CT scans ranged from 1.46 to 1.69 times the pre-implant prostate volume (mean: 1.55, standard deviation: 0.08).

Discussion

When the clinicians and physicists at New York’s Mt. Sinai Hospital began their prostate implant program (1990), they adopted the Memorial Hospital nomogram to determine the total activity to implant for a given prostate volume. It became apparent, however, that the nomogram developed for Memorial’s homogenous seed distribution was inappropriate for Sinai’s peripherally-loaded implants. In a series of 5 iterations over 5 years, the Sinai program developed an institution-specific nomogram to satisfy their needs [16]. When our institution switched from 125I to 131Cs seeds, we relied on guidelines that had been developed elsewhere. We, too, were disappointed with our dosimetric outcomes and endeavored to develop a nomogram that reflected our implant pattern and dosimetric constraints.
Nomograms had once been used to determine total implant activity, seed number, and spacing [7]. We believe that computer planning has reduced, but not eliminated the utility of nomograms. Nomograms can be used for quality control and to maintain consistency among implant plans. The VariSeed software utilizes a ‘Nomogram Planning Module’ to generate a complete treatment plan (including total activity, needle, and source positions), but relies on a nomogram entered by the operator. It may be unsatisfactory to adopt a ‘generic’ nomogram obtained from medical literature or provided by a seed distributor, as it has been demonstrated that experienced brachytherapists espousing the same implant philosophy and prescribing to the same dose will implant the same volume with a different number of seeds and total activity [17]. Indeed, the variation in total implant activity can exceed 40% [15]. It has therefore been recommended that a nomogram be generated to reflect an institution’s own practices [3,15].
It has long been appreciated that the edema engendered by prostate implantation can degrade implant quality [18-20]. If the magnitude of swelling could be predicted, it would be a simple matter to compensate by a reciprocal increase in implant strength; but the magnitude is highly variable and unpredictable [18-20]. Two strategies have been commonly used to reduce the impact of swelling on implant quality:
1. Devising a treatment plan in which the target volume encompasses the prostate with a several millimeter margin [21]. Use of our nomogram has resulted in the delivery of prescription dose to a volume 47-69% greater than the pre-implant prostate volume (coinciding with previously observed day-1 swelling), without exceeding normal tissue constraints or placement of extracapsular seeds.
2. Utilizing intra-operative treatment planning with computer optimization [13]. Unless the brachytherapist orders seeds in bulk (impractical for small programs and those utilizing short half-life radionuclides), a method is required for predicting the number and strength seeds that will be used.
It has been proposed that nomograms can be used to at least partially compensate for implant-induced edema [22]; our experience suggests this to be so. The technique we have proposed for nomogram generation utilizes ubiquitous software; it has been utilized by one of the authors (JNA) for over a decade. His nomogram has been revised whenever his technique was modified or a new radionuclide was adopted (the process facilitates changing of radionuclides, as the post-implant CT scans performed after implantation with the ‘old’ radionuclide can be used to generate a nomogram for the ‘new’ one).
Nomograms can be based on either linear or power equations. Historically, power equations have been most often used, but it had previously been demonstrated that, for the range of volumes typically implanted, a power curve is almost ‘linear’ [23]; our current experience confirms this (Fig. 1). Indeed, the calculated difference between our linear and power equations was less than one seed for prostate volumes between 25 and 45 mL (data not shown). We suggest that practitioners generate both power and linear equations, and use the equation that has the better fit (higher R2). We wish to stress that nomograms may have a supplementary role in treatment planning, and do not diminish the centrality of computer dosimetry in brachytherapy planning.

Conclusions

Computer dosimetry has diminished, but not eliminated the role of nomograms in prostate brachytherapy. They remain useful for estimating the total activity and number of sources to be implanted. Our experience suggests that they can partially compensate for the unpredictable degree of post-implant edema. Brachytherapists should use nomograms that reflect their own implant practices, tissue constraints, and philosophy. We have demonstrated a simple method for the generation of institution-specific nomograms for permanent prostate brachytherapy.

Disclosure

Authors report no conflict of interest.

References

1. Wang X-H, Potters L. A theoretical derivation of the nomograms for permanent prostate brachytherapy. Med Phys 2001; 28: 683-687.
2. D’Souza WD, Lee HK, Palmer MB et al. Is intraoperative nomogram-based overplanning of prostate implants necessary? Int J Radiat Oncol Biol Phys 2003; 56: 462-467.
3. Al-Qaisieh B, Brearley E, Clair SS et al. A study of a pretreatment method to predict the number of I-125 seeds required for prostate brachytherapy. Int J Radiat Oncol Biol Phys 2006; 65: 304-307.
4. Kudchadker RJ, Swanson DA, Kuban DA et al. Is a loose-seed nomogram still valid for prostate brachytherapy in a stranded- seed era? Int J Radiat Oncol Biol Phys 2008; 72: 623-627.
5. Langley SEM, Laing RW. 4D brachytherapy, a novel real- time prostate brachytherapy technique using stranded and loose seeds. BJU Internat 2012; 109: s1-6.
6. Li T, Fountain BL, Duffy EW. Physical derivation of nomograms in permanent prostate brachytherapy. Brachytherapy 2010; 9: 50-54.
7. Anderson LL. Spacing nomograph for interstitial implants of I-125 seeds. Med Phys 1976; 3: 48-51.
8. Yu Y, Schell MC. A genetic algorithm for the optimization of prostate implants. Med Phys 1996; 23: 2085-2091.
9. McNeely LK, Stone NN, Presser J et al. Influence of prostate volume on dosimetry results in real-time I-125 seed implantation. Int J Radiat Oncol Biol Phys 2004; 58: 292-299.
10. Stone NN, Stock RG. Brachytherapy for prostate cancer: Real- time three-dimensional interactive seed implantation. Tech Urol 1995; 1: 72-80.
11. Wu A, Lee C-C, Johnson M, Brown D et al. A new power law for determination of total I-125 seed activity for ultra-sound-guided prostate implants: clinical evaluations. Int J Radiat Oncol Biol Phys 2000; 47: 1397-1403.
12. Anderson LL, Moni JV, Harrison LB. A nomograph for permanent implants of palladium-103 seeds. Int J Radiat Oncol Biol Phys 1993; 27: 129-135.
13. Zelefsky MJ, Yamada Y, Cohen G et al. Postimplantation dosimetric analysis of permanent transperineal prostate implantation: Improved dose distributions with an intraoperative computer-optimized conformal planning technique. Int J Radiat Oncol Biol Phys 2000; 48: 601-608.
14. Raben A, Chen H, Grebler A et al. Prostate seed implantation using 3D-computer assisted intraoperative planning vs. a standard look-up nomogram: Improved target conformality with reduction in urethral and rectal wall dose. Int J Radiat Oncol Biol Phys 2004; 60: 1631-1638.
15. Aronowitz JN, Crook JM, Michalski JM et al. Inter-institutional variation of implant activity for permanent prostate brachytherapy. Brachytherapy 2008; 7: 297-300.
16. Stone NN, Stock RG, DeWyngaert JK et al. Prostate brachytherapy: Improvements in prostate volume measurements and dose distribution using interactive ultrasound guided implantation and three-dimensional dosimetry. Radiat Oncol Invest 1995; 3: 185-195.
17. Merrick GS, Butler WM, Wallner KE et al. Vaariability of prostate brachytherapy preimplant dosimetry: a multi-institutional analysis. Brachytherapy 2005; 4: 241-251.
18. Prestidge BR, Bice WS, Kiefer EJ et al. Timing of computed tomography-based postimplant assessment following permanent transperineal prostate brachytherapy. Int J Radiat Oncol Biol Phys 1998; 40: 1111-1115.
19. Waterman FM, Yue N, Corn B et al. Edema associated with I-125 or Pd-103 prostate brachytherapy and its impact on post-implant dosimetry: an analysis based on serial CT acquisition. Int J Radiat Oncol Biol Phys 1998; 41: 1069-1077.
20. Dogan N, Mohideen N, Glasgow GP et al. Effect of prostatic edema on CT-based postimplant dosimetry. Int J Radiat Oncol Biol Phys 2002; 53: 483-489.
21. Waterman FM, Dicker AP. Impact of post-implant edema on V100 and D90 in prostate brachytherapy: Can implant quality be predicted on day 0? Int J Radiat Oncol Biol Phys 2002; 53: 610-621.
22. Potters L, Wang XH, Yamada Y. A nomogram to compensate for intraoperative prostate edema during transperineal brachytherapy. Tech Urol 2000; 6: 99-103.
23. Aronowitz JN, Michalski JM, Merrick GS et al. Optimal equations for describing the relationship between prostate volume, number of sources, and total activity in prostate brachytherapy. Am J Clin Oncol 2010; 33: 164-167.
Copyright: © 2014 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.