eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

3/2014
vol. 6
 
Share:
Share:
abstract:

Original paper
Distinguishing prostate-specific antigen bounces from biochemical failure after low-dose rate prostate brachytherapy

Cian Hackett
,
Sunita Ghosh
,
Ron Sloboda
,
Kevin Martell
,
Lanna Lan
,
Nadeem Pervez
,
John Pedersen
,
Don Yee
,
Albert Murtha
,
John Amanie
,
Nawaid Usmani

J Contemp Brachytherapy 2014; 6, 3: 247–253
Online publish date: 2014/09/05
View full text Get citation
 
Purpose The purpose of this study was to characterize benign prostate-specific antigen (PSA) bounces of at least 2.0 ng/mL and biochemical failure as defined by the Phoenix definition after prostate brachytherapy at our institution, and to investigate distinguishing features between three outcome groups: patients experiencing a benign PSA bounce, biochemical failure, or neither.

Material and methodss: Five hundred and thirty consecutive men treated with low-dose-rate brachytherapy with follow-up of at least 3 years were divided into outcome groups experiencing bounce, failure, or neither. A benign bounce was defined as a rise of at least 2.0 ng/mL over the pre-rise nadir followed by a decline to 0.5 ng/mL or below, without intervention. Patient and tumor characteristics, treatment variables, and PSA kinetics were analyzed between groups.

Results Thirty-two (6.0%) men experienced benign bounces and 47 (8.9%) men experienced failure. Men experiencing a bounce were younger (p = 0.01), had a higher 6-month PSA level (p = 0.03), and took longer to reach a final nadir (p < 0.01). Compared to the failure group, men with bounce had a lower pre-treatment PSA level (p = 0.01) and experienced a rise of at least 2.0 ng/mL that occurred sooner after the implant (p < 0.01) with a faster PSA doubling time (p = 0.01). Only time to PSA rise independently differentiated between bounce and failure (p < 0.01), with a benign bounce not being seen after 36 months post-treatment. Prostate-specific antigen levels during a bounce reached levels as high as 12.6 ng/mL in this cohort, and in some cases took over 5 years to decline to below 0.5 ng/mL.

Conclusions: Although there is substantial overlap between the features of benign PSA bounces and failure, physicians may find it useful to evaluate the timing, absolute PSA level, initial response to treatment, and rate of rise when contemplating management for a PSA rise after low-dose-rate brachytherapy.
keywords:

brachytherapy, prostatic neoplasms, prostate-specific antigen, relapse

 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.