Purpose
Patients diagnosed with localized prostate cancer face a myriad of established treatment options including active surveillance, radical prostatectomy, external beam radiotherapy, brachytherapy, androgen deprivation therapy or combinations of two or more of the above. The choice of therapy depends on such factors as risk grouping (based on stage, Gleason score, and prostate specific antigen [PSA] level), bulk of disease (e.g. percentage of core positivity), urinary symptoms, patient age, and co-morbidities, patient preference and access to treatment. For patients being treated with radiation, decisions include whether to use external beam alone, brachytherapy alone, a combination of both, and the additional value of adjuvant androgen deprivation therapy. If brachytherapy is a component of treatment, either permanent seed or high-dose-rate (HDR) options are possible.
This review will focus on the use of HDR brachytherapy as a boost in combination with external beam radiotherapy, with particular attention to rationale, choice of dose, and technique.
Material and methods
Online searches through PubMed and MEDLINE were conducted using the search terms “brachytherapy”, “high-dose-rate”, “prostate cancer”, “HDR”, and “boost”. Abstracts were reviewed and suitable full texts manuscripts obtained. Priority was given to publications within the past
5 years, with a minimum of 100 patients, and median follow-up of at least 5 years. Data was complemented by personal and institutional experience.
Results
Interstitial brachytherapy using remote afterloading of a small, very high activity iridium-192 (192Ir) source has been used to treat prostate cancer since the 1980’s [1]. In contrast to seed brachytherapy where there was a risk of inadequate post-implant dosimetry due to seed loss or misplacement, HDR dosimetry was performed with the catheters in place resulting in consistently higher target coverage [2]. Results of early clinical trials using HDR as a conformal boost in combination with external beam radiotherapy (EBRT) were encouraging, demonstrating low rates of acute toxicity [3], and a high rate of cancer control [4]. Early data reported that HDR boost resulted in lower nadir PSA values and higher cancer control rates than EBRT alone [5].
Rationale for high-dose-rate boost
High-dose-rate is used as a method of conformal dose escalation in combination with EBRT for the following reasons: 1) external beam dose escalation above 70-76 Gy is required to optimize probability of cancer control; 2) HDR allows an unequalled degree of dose conformity to target and sparing of adjacent organs at risk; 3) the postulated low /β ratio of prostate cancer provides radiobiological rationale for hypofractionation or HDR; 4) a wealth of clinical data supports its use.
The importance of external beam dose has been firmly established with mature results from several randomized controlled trials [6-10]. These demonstrate that external beam dose escalation from 68-70 Gy to 78-80 Gy results in a 10-15% decrease in risk of biochemical failure, albeit with uncertain effect on other clinically meaningful endpoints such as local control, risk of metastases and survival. Furthermore, the improvement in biochemical recurrence rate usually comes at a cost of increased rectal toxicity, although it is hoped that advances in external beam technique will enable dose escalation without an increase in adverse events [11]. The improvement in biochemical control with external beam dose escalation appears to be greatest for patients with intermediate or high risk disease [12,13], with clinical benefit particularly for those under the age of 70 years. The dose to which patients can safely be treated with external beam radiotherapy is limited by the tolerance of surrounding organs at risk and limitations due to inter and intra-fraction organ movement. Hypofractionation has been investigated as a method of external beam biological dose escalation, but randomized trials still make the relative efficacy of this approach uncertain [14].
Brachytherapy boost has also been investigated as a method of dose escalation in randomized trials. Sathya et al. performed an early randomized trial comparing a boost using low-dose-rate 192Ir to external beam radiotherapy alone in patients with locally advanced prostate cancer [15]. Patients randomized to receive 40 Gy EBRT and a 35 Gy brachytherapy boost had a biochemical failure rate of 29% compared to a failure rate of 61% in those randomized to receive 66 Gy with EBRT alone. Although the EBRT dose is low by modern standards, the study confirmed the principle that brachytherapy boost in combination with moderate dose EBRT resulted in higher cancer control rates than that achievable with EBRT alone. Hoskin et al. have completed a randomized trial of HDR boost in a cohort of patients with mostly intermediate and high risk disease [16]. Patients were randomized to receive either EBRT alone to a dose of 55 Gy in 20 fractions, or HDR boost (17 Gy/2 fractions) combined with EBRT to a dose of 35.75 Gy in 13 fractions. Those in the HDR boost arm had a 31% reduction in risk of recurrence. Once again, the EBRT dose would be considered low by contemporary standards, with an equivalent dose of approximately 68 Gy at standard fractionation.
Either HDR or permanent seed brachytherapy is capable of delivering higher dose with greater conformity than any external beam technique [17]. Yoshioka et al. recently detailed the rationale for HDR as monotherapy, and similar considerations hold for use of HDR as a boost [18]. The high degree of conformity achievable with HDR makes it a particularly attractive method of dose escalation. Because dose optimization is performed after placement of catheters, HDR enables more consistent target coverage than permanent seed implants with greater dose uniformity, and lower dose to urethra and rectum [19]. While there is some evidence that HDR monotherapy is associated with less toxicity than permanent seed implant monotherapy, there is a paucity of clinical outcome data comparing HDR and permanent seeds as boost [20].
High-dose-rate delivers better dosimetry than any form of external beam radiotherapy. In a dosimetric study by Georg et al., radiation dose to normal tissues including rectal and bladder wall was significantly lower with brachytherapy (either HDR or permanent seeds) compared to the most advanced external techniques of volumetric modulated arc therapy (VMAT), intensity modulated proton therapy or scanned carbon-ion therapy [21]. The lowest dose to normal tissues was obtained with HDR. Spratt et al. drew a similar conclusion comparing HDR dosimetry with that of stereotactic body radiotherapy (SBRT) – HDR delivers a higher dose within the prostate and lower dose to adjacent organs at risk [22].
It is likely that the mean /β ratio for prostate cancer is very low, possibly less than 1.0 [23]. This is lower than the /β ratio of adjacent normal tissues, and would suggest that prostate cancer cells are more sensitive to radiation delivered in large fraction size than are normal tissue cells in the adjacent rectum. This provides radiobiological rationale for HDR as a method of biological dose escalation without exceeding tolerance of adjacent organs.
Perhaps the main justification for use of HDR as a boost is the wealth of clinical data supporting its use [24]. As can be seen from Table 1, many mature single centre series have been reported from around the world, including almost 5000 patients and with a median follow- up of up to 10 years [25-46]. Despite significant variability in dose and fractionation used, reported biochemical disease-free survival is consistently high – on average 95% for low risk, 91% for intermediate risk and 82% for high risk. Treatment is well tolerated – late grade 3 rectal toxicity is rare, while late grade 3 urinary toxicity (most commonly stricture) is reported in 1-14% of series.
As yet there are no completed randomized trials comparing outcome of HDR boost with that of modern dose-escalated image-guided external beam radiotherapy. An ongoing trial of the National Cancer Institute of Canada (Clinical Trials.Gov identifier NCT01982786) randomizes men with intermediate risk prostate cancer to receive either an HDR boost of 15 Gy combined with 37.5 Gy image guided EBRT in 15 fractions, or else image guided EBRT alone to either a dose of 78 Gy in 39 fractions or 60 Gy in 20 fractions. The available data to date, however, strongly suggests that HDR boost results in a higher disease-free survival than dose escalated external beam alone for most men with prostate cancer. Spratt et al. reported outcome data on 870 consecutive patients with intermediate risk prostate treated with either IMRT alone to 86.4 Gy, or 50.4 Gy IMRT with a brachytherapy boost – either permanent seed or HDR [47]. With a median follow-up of 5.3 years, both the biochemical disease-free survival and distant metastases-free survival rates were significantly higher in the brachytherapy boost patients at 92% vs. 81%, and 97% vs. 93% for brachytherapy boost and IMRT, respectively. The IMRT dose used in this report is the highest that can safely be delivered. Late genitourinary toxicity rates were similar in both arms, suggesting that the improved clinical outcomes were obtained without an increase in side-effects.
In summary, HDR brachytherapy boost results in a high disease control rates for men with localized prostate cancer, with a strong suggestion that it is more effective than external beam radiotherapy alone.
High-dose-rate dose and technique
The consensus guidelines of the American Brachytherapy Society notes that similar excellent clinical outcomes are reported by investigators using a wide range of dose and fractionation, and as such is unable to recommend a particular dose fractionation schedule [48]. GEC/ESTRO have updated their recommendations on prostate HDR [49]. They also acknowledge that it is not possible to recommend one specific dose prescription, but reference the following external beam schedules (Table 2). The choice of dose and fractionation should be safe, effective, acceptable to patients, and make efficient use of available resources.
At Sunnybrook Odette Cancer Centre in Toronto, we have adopted a boost policy of 15 Gy HDR as a single fraction, combined with EBRT to a dose of 37.5 Gy in 15 fractions over 3 weeks. This protocol began as a Phase II clinical trial for patients with intermediate risk prostate cancer in 2005 [38]. At a median follow-up of 6.2 years, the 5-year biochemical disease-free survival (Phoenix definition) is over 97% (95% confidence intervals: 93-99%) (Fig. 1). Clinical efficacy and toxicity are similar to that of our previous protocol of HDR delivered in two fractions of 10 Gy and an external beam dose of 45 Gy in 25 fractions. It is, however, more acceptable to patients and makes more efficient use of resources. The protocol has been widely adopted across Canada, the United Kingdom, and in many U.S. centers. A single 15 Gy has become the standard HDR boost dose in current Radiation Therapy Oncology Group clinical trials (RTOG 0924 and RTOG 1115). It remains well tolerated with a Grade 3 or higher late toxicity rate of < 5%.
Technique
The choice of HDR technique will depend on physician preference and local resources. Key steps are: 1) catheter placement under image guidance; 2) imaging with catheters in place; 3) contouring of target(s), organs at risk, and catheter reconstruction on planning system; 4) dwell time optimization to achieve dosimetric constraints; 5) quality assurance, including second checks on plan and catheter positions; 6) treatment delivery.
For single fractions, treatment is usually delivered on an outpatient basis, allowing the patient to go home once recovered from the anesthetic. If multiple fractions are to be delivered with the same implant, the patient is usually admitted with appropriate analgesia. It is vitally important to check on catheter position, and re-position or re-plan if necessary, before each fraction delivery.
Catheters are most commonly placed under TRUS guidance. This is cheap, quick, and readily available. Computed tomography or MR guided insertions have also been reported [50]. Either rigid (steel or titanium) or flexible catheters may be used. Rigid catheters are sharper and easier to steer, but tend to cause more artifact, usually have a larger “dead space” at the tip and need to be re-sterilized. Flexible catheters are more comfortable for the patient if they are to be left in place and are disposable. Most centers use a template to help guide the catheters to desired location, although a free-hand technique using dental putty to fix catheters in place is an alternative [51].
At Sunnybrook, our technique involves using flexible catheters inserted with a template fixed to the ultrasound stepper. Rather than optimizing placement of each catheter, a standard catheter arrangement is used as indicated in Figure 2. An arrangement of 16 catheters is suitable for most patients. Catheters are placed symmetrically. The anterior 4 catheters define the anterior anatomic border of the prostate at the mid-plane. The next 2 rows of catheters are placed approximately 1 cm apart, with the medial catheters 1 cm away from the urethra. Ideally, the fourth and final row is 5 mm away from the posterior border of the prostate. This arrangement of catheters allows for consistently high target coverage with adequate sparing of the urethra and rectum.
Imaging is then performed with the catheters in place for planning. Computed tomography or TRUS is most commonly used. Computed tomography has the advantage of high catheter visibility, but in most institutions requires transfer of the patient to another room or department following fixation of the catheters and template to the perineum (Fig. 2). The patient then needs to be transported back to the brachytherapy room for treatment. Each patient transfer and change in position (e.g. lowering of legs) risks catheter displacement, which needs to be evaluated and corrected for. At the Sunnybrook Odette Cancer Centre, we reported an average catheter displacement of over 1 cm between the time of CT and treatment delivery despite careful suturing of the template to the perineum [52]. If uncorrected, this would have resulted in a significant degradation of the plan, with a 20% decrease in target coverage and a significant increase in urethral dose – particularly the bulbomembranous urethra (Fig. 3). If CT planning is being utilized, a careful quality assurance process is required to correct for any such displacement.
TRUS-based planning is usually performed in real time in the operating room with the ultrasound probe in place and the patient still under anesthetic (Fig. 4). The patient is then treated in the same position. There is therefore no risk of catheter displacement, and the planned dosimetry is that delivered. TRUS-based planning is particularly suitable for single fraction treatments. Ideally however, it requires a shielded operating room, so that the treatment can be delivered without moving the patient. This is not always a possibility. Further disadvantages of TRUS-based planning include occasional difficulty identifying the catheters and inability to contour the bladder. However, if a shielded operating room is available, TRUS-based planning is a more efficient, reliable, and accurate method of HDR planning than CT. In our experience, the average time between catheter insertion and treatment delivery was 6 hours with CT based planning and 1.5 hours with TRUS-based planning.
Once planning images have been obtained, dwell time optimization is performed to meet the dosimetric constraints using anatomy-based inverse planning [53]. A wide range of dose constraints is used by different centers. There is evidence that maintaining a high target coverage (volume receiving 100% of prescription dose, V100, or dose to 90%, D90) is important for disease control, and that dose to urethra is the most important predictor of long-term urinary morbidity [54-56]. GEC-ESTRO has proposed a number of reasonable dosimetric constraints for both target and organs at risk as follows [49] (Table 3).
There was insufficient data to provide recommendations on bladder or penile bulb dose limits. Expressing dose limits in terms of EQD2 enables adjustment for different fractionation schedules and external beam dose regimens.
At Sunnybrook, HDR is delivered using a real-time intra-operative technique, and the external beam is delivered using volumetric arc therapy (VMAT). This provides greater efficiency than previous techniques, with continued low incidence of morbidity. For an HDR prescription dose of 15 Gy to the clinical target volume, the V100 is maintained > 95% (median 97.5%). V150 between 30-35% and V200 < 14%. The urethra D10 is constrained to < 118% (median 116%), maximal urethral dose < 130% (median 120%), and rectal V80 < 0.6 cc (median 0.1 cc). The standard external beam dose is 37.5 Gy in 15 fractions over 3 weeks to the prostate and proximal seminal vesicles.
Summary and Conclusions
High-dose-rate brachytherapy combined with external radiotherapy is associated with a high cancer control rate for patients with intermediate and high risk disease. While a wide range of dose and fractionations can be used, a single 15 Gy combined with 37.5 Gy EBRT in 15 fractions is well tolerated and associated with excellent long-term disease control rates. The role of adjuvant androgen deprivation therapy is not well established in the context of HDR boost, but is reasonable to consider for patients with higher risk disease.
Disclosure
Author reports no conflict of interest.
References
1. Bentzen JK, Ockelmann HH, Hansen HS. High dose rate 192ir-microselectron. Ugeskr Laeger 1990; 152: 2908-2910 [in Danish].
2. Mate TP, Gottesman JE, Hatton J et al. High dose-rate afterloading 192Iridium prostate brachytherapy: feasibility report. Int J Radiat Oncol Biol Phys 1998; 41: 525-533.
3. Stromberg J, Martinez A, Gonzalez J et al. Ultrasound-guided high dose rate conformal brachytherapy boost in prostate cancer: treatment description and preliminary results of a phase I/II clinical trial. Int J Radiat Oncol Biol Phys 1995; 33: 161-171.
4. Kovacs G, Galalae R, Loch T et al. Prostate preservation by combined external beam and HDR brachytherapy in nodal negative prostate cancer. Strahlenther Onkol 1999; 175 Suppl 2: 87-88.
5. Kestin LL, Martinez AA, Stromberg JS et al. Matched-pair analysis of conformal high-dose-rate brachytherapy boost versus external-beam radiation therapy alone for locally advanced prostate cancer. J Clin Oncol 2000; 18: 2869-2880.
6. Kuban DA, Tucker SL, Dong L et al. Long-term results of the M. D. Anderson randomized dose-escalation trial for prostate cancer. Int J Radiat Oncol Biol Phys 2008; 70: 67-74.
7. Zietman AL, Bae K, Slater JD et al. Randomized trial comparing conventional-dose with high-dose conformal radiation therapy in early-stage adenocarcinoma of the prostate: long-term results from proton radiation oncology group/american college of radiology 95-09. J Clin Oncol 2010; 28: 1106-1111.
8. Beckendorf V, Guerif S, Le Prise E et al. 70 Gy versus 80 Gy in localized prostate cancer: 5-year results of GETUG 06 randomized trial. Int J Radiat Oncol Biol Phys 2011; 80: 1056-1063.
9. Al-Mamgani A, van Putten WL, van der Wielen GJ et al. Dose escalation and quality of life in patients with localized prostate cancer treated with radiotherapy: long-term results of the Dutch randomized dose-escalation trial (CKTO 96-10 trial). Int J Radiat Oncol Biol Phys 2011; 79: 1004-1012.
10. Dearnaley DP, Sydes MR, Graham JD et al. Escalated-dose versus standard-dose conformal radiotherapy in prostate cancer: first results from the MRC RT01 randomised controlled trial. Lancet Oncol 2007; 8: 475-487.
11. Michalski JM, Yan Y, Watkins-Bruner D et al. Preliminary toxicity analysis of 3-dimensional conformal radiation therapy versus intensity modulated radiation therapy on the high-dose arm of the Radiation Therapy Oncology Group 0126 prostate cancer trial. Int J Radiat Oncol Biol Phys 2013; 87: 932-938.
12. Al-Mamgani A, Heemsbergen WD, Levendag PC et al. Subgroup analysis of patients with localized prostate cancer treated within the Dutch-randomized dose escalation trial. Radiother Oncol 2010; 96: 13-18.
13. Kuban DA, Levy LB, Cheung MR et al. Long-term failure patterns and survival in a randomized dose-escalation trial for prostate cancer. Who dies of disease? Int J Radiat Oncol Biol Phys 2011; 79: 1310-1317.
14. Pollack A, Walker G, Horwitz EM et al. Randomized trial of hypofractionated external-beam radiotherapy for prostate cancer. J Clin Oncol 2013; 31: 3860-3868.
15. Sathya JR, Davis IR, Julian JA et al. Randomized trial comparing iridium implant plus external-beam radiation therapy with external-beam radiation therapy alone in node-negative locally advanced cancer of the prostate. J Clin Oncol 2005; 23: 1192-1199.
16. Hoskin PJ, Rojas AM, Bownes PJ et al. Randomised trial of external beam radiotherapy alone or combined with high-dose-rate brachytherapy boost for localised prostate cancer. Radiother Oncol 2012; 103: 217-222.
17. Skowronek J. Low-dose-rate or high-dose-rate brachytherapy in treatment of prostate cancer - between options. J Contemp Brachytherapy 2013; 5: 33-41.
18. Yoshioka Y, Suzuki O, Otani Y et al. High-dose-rate brachytherapy as monotherapy for prostate cancer: technique, rationale and perspective. J Contemp Brachytherapy 2014; 6: 91-98.
19. Wang Y, Sankreacha R, Al-Hebshi A et al. Comparative study of dosimetry between high-dose-rate and permanent prostate implant brachytherapies in patients with prostate adenocarcinoma. Brachytherapy 2006; 5: 251-255.
20. Grills IS, Martinez AA, Hollander M et al. High dose rate brachytherapy as prostate cancer monotherapy reduces toxicity compared to low dose rate palladium seeds. J Urol 2004; 171: 1098-1104.
21. Georg D, Hopfgartner J, Gora J et al. Dosimetric considerations to determine the optimal technique for localized prostate cancer among external photon, proton, or carbon-ion therapy and high-dose-rate or low-dose-rate brachytherapy. Int J Radiat Oncol Biol Phys 2014; 88: 715-722.
22. Spratt DE, Scala LM, Folkert M et al. A comparative dosimetric analysis of virtual stereotactic body radiotherapy to high-dose-rate monotherapy for intermediate-risk prostate cancer. Brachytherapy 2013; 12: 428-433.
23. Vogelius IR, Bentzen SM. Meta-analysis of the alpha/beta ratio for prostate cancer in the presence of an overall time factor: bad news, good news, or no news? Int J Radiat Oncol Biol Phys 2013; 85: 89-94.
24. Morton GC, Hoskin PJ. Brachytherapy: current status and future strategies – can high dose rate replace low dose rate and external beam radiotherapy? Clin Oncol (R Coll Radiol) 2013; 25: 474-482.
25. Agoston P, Major T, Frohlich G et al. Moderate dose escalation with single-fraction high-dose-rate brachytherapy boost for clinically localized intermediate- and high-risk prostate cancer: 5-year outcome of the first 100 consecutively treated patients. Brachytherapy 2011; 10: 376-384.
26. Aluwini S, van Rooij PH, Kirkels WJ et al. High-dose-rate brachytherapy and external-beam radiotherapy for hormone-naive low- and intermediate-risk prostate cancer: a 7-year experience. Int J Radiat Oncol Biol Phys 2012; 83: 1480-1485.
27. Bachand F, Martin AG, Beaulieu L et al. An eight-year experience of HDR brachytherapy boost for localized prostate cancer: biopsy and PSA outcome. Int J Radiat Oncol Biol Phys 2009; 73: 679-684.
28. Cury FL, Duclos M, Aprikian A et al. Single-fraction high-dose-rate brachytherapy and hypofractionated external beam radiation therapy in the treatment of intermediate-risk prostate cancer – long term results. Int J Radiat Oncol Biol Phys 2012; 82: 1417-1423.
29. Deutsch I, Zelefsky MJ, Zhang Z et al. Comparison of PSA relapse-free survival in patients treated with ultra-high-dose IMRT versus combination HDR brachytherapy and IMRT. Brachytherapy 2010; 9: 313-318.
30. Galalae RM, Zakikhany NH, Geiger F et al. The 15-year outcomes of high-dose-rate brachytherapy for radical dose escalation in patients with prostate cancer-A benchmark for high-tech external beam radiotherapy alone? Brachytherapy 2014; 13: 117-122.
31. Ghadjar P, Rentsch CA, Isaak B et al. Urethral toxicity vs. cancer control – lessons to be learned from high-dose rate brachytherapy combined with intensity-modulated radiation therapy in intermediate- and high-risk prostate cancer. Brachytherapy 2010; 10: 286-294.
32. Kaprealian T, Weinberg V, Speight JL et al. High-dose-rate brachytherapy boost for prostate cancer: comparison of two different fractionation schemes. Int J Radiat Oncol Biol Phys 2012; 82: 222-227.
33. Khor R, Duchesne G, Tai KH et al. Direct 2-arm comparison shows benefit of high-dose-rate brachytherapy boost vs external beam radiation therapy alone for prostate cancer. Int J Radiat Oncol Biol Phys 2013; 85: 679-685.
34. Kotecha R, Yamada Y, Pei X et al. Clinical outcomes of high-dose-rate brachytherapy and external beam radiotherapy in the management of clinically localized prostate cancer. Brachytherapy 2013; 12: 44-49.
35. Lilleby W, Tafjord G, Raabe NK. Implementation of high-dose-rate brachytherapy and androgen deprivation in patients with prostate cancer. Int J Radiat Oncol Biol Phys 2012; 83: 933-939.
36. Marina O, Gustafson GS, Kestin LL et al. Comparison of dose-escalated, image-guided radiotherapy vs. dose-escalated, high-dose-rate brachytherapy boost in a modern cohort of intermediate-risk prostate cancer patients. Brachytherapy 2014; 13: 59-67.
37. Martínez-Monge R, Moreno M, Ciérvide R et al. External- beam radiation therapy and high-dose rate brachytherapy combined with long-term androgen deprivation therapy in high and very high prostate cancer: preliminary data on clinical outcome. Int J Radiat Oncol Biol Phys 2012; 82: e469-476.
38. Morton G, Loblaw A, Cheung P et al. Is single fraction 15 Gy the preferred high dose-rate brachytherapy boost dose for prostate cancer? Radiother Oncol 2011; 100: 463-467.
39. Neviani CB, Miziara MA, de Andrade Carvalho H. Results of high dose-rate brachytherapy boost before 2D or 3D external beam irradiation for prostate cancer. Radiother Oncol 2011; 98: 169-174.
40. Pellizzon AC, Salvajoli J, Novaes P et al. Updated results of high-dose rate brachytherapy and external beam radiotherapy for locally and locally advanced prostate cancer using the RTOG-ASTRO Phoenix definition. Int Braz J Urol 2008; 34: 293-301.
41. Phan TP, Syed AM, Puthawala A et al. High dose rate brachytherapy as a boost for the treatment of localized prostate cancer. J Urol 2007; 177: 123-127; discussion 127.
42. Pistis F, Guedea F, Pera J et al. External beam radiotherapy plus high-dose-rate brachytherapy for treatment of locally advanced prostate cancer: the initial experience of the Catalan Institute of Oncology. Brachytherapy 2010; 9: 15-22.
43. Prada PJ, Gonzalez H, Fernandez J et al. Biochemical outcome after high-dose-rate intensity modulated brachytherapy with external beam radiotherapy: 12 years of experience. BJU Int 2012; 109: 1787-1793.
44. Savdie R, Symons J, Spernat D et al. High-dose rate brachytherapy compared with open radical prostatectomy for the treatment of high-risk prostate cancer: 10 year biochemical freedom from relapse. BJU Int 2012; 110 Suppl 4: 71-76.
45. Whalley D, Patanjali N, Jackson M et al. HDR brachytherapy combined with external beam radiation for localised prostate cancer: early experience from the Sydney Cancer Centre. J Med Imaging Radiat Oncol 2012; 56: 220-226.
46. Zwahlen DR, Andrianopoulos N, Matheson B et al. High-dose-rate brachytherapy in combination with conformal external beam radiotherapy in the treatment of prostate cancer. Brachytherapy 2010; 9: 27-35.
47. Spratt DE, Zumsteg ZS, Ghadjar P et al. Comparison of high-dose (86.4 Gy) IMRT vs combined brachytherapy plus IMRT for intermediate-risk prostate cancer. BJU Int 2014; 114: 360-367.
48. Yamada Y, Rogers L, Demanes DJ et al. American Brachytherapy Society consensus guidelines for high-dose-rate prostate brachytherapy. Brachytherapy 2012; 11: 20-32.
49. Hoskin PJ, Colombo A, Henry A et al. GEC/ESTRO recommendations on high dose rate afterloading brachytherapy for localised prostate cancer: an update. Radiother Oncol 2013; 107: 325-332.
50. Menard C, Susil RC, Choyke P et al. MRI-guided HDR prostate brachytherapy in standard 1.5T scanner. Int J Radiat Oncol Biol Phys 2004; 59: 1414-1423.
51. Kim Y, Hsu IC, Pouliot J. Measurement of craniocaudal catheter displacement between fractions in computed tomography-based high dose rate brachytherapy of prostate cancer. J Appl Clin Med Phys 2007; 8: 2415.
52. Holly R, Morton GC, Sankreacha R et al. Use of cone-beam imaging to correct for catheter displacement in high dose-rate prostate brachytherapy. Brachytherapy 2011; 10: 299-305.
53. Morton GC, Sankreacha R, Halina P et al. A comparison of anatomy-based inverse planning with simulated annealing and graphical optimization for high-dose-rate prostate brachytherapy. Brachytherapy 2008; 7: 12-16.
54. Hoskin PJ, Rojas AM, Ostler PJ et al. Dosimetric predictors of biochemical control of prostate cancer in patients randomised to external beam radiotherapy with a boost of high dose rate brachytherapy. Radiother Oncol 2014; 110: 110-113.
55. Hsu IC, Hunt D, Straube W et al. Dosimetric analysis of radiation therapy oncology group 0321: The importance of urethral dose. Pract Radiat Oncol 2014; 4: 27-34.
56. Morton GC, Loblaw DA, Chung H et al. Health-related quality of life after single-fraction high-dose-rate brachytherapy and hypofractionated external beam radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 2011; 80: 1299-1305.